PRO208V-5k75 Installation and Safety Manual
900-0203-01-00 Rev B
38
7.4.
Notes on Selected Issues
Inverter Button Indicator States
If there is power to the inverter, the indicator on the inverter button
will be indicating something. As described earlier, these have the
following meanings and operations:
Inverter Button Push
Button Indication
3
Result
1 press
•
Make inverter beep (“are you alive?”)
2 presses
•
Off & Locked
(disabled)
•
Unit will not begin the 5-minute self-start
3 presses
•
Start generating immediately
•
If locked, unlock and generate immediately
•
If system is faulted, unit will unlock but
will not generate
Long press (>2 seconds)
(Brief flash)
•
“Alternate functions” mode
•
Ready to accept further button pushes;
this times out after 10 seconds
1 press (after long press)
•
Clear latched faults after (for example)
an arc-fault test or RCD (residual-current device)
test initiated a fault condition
4 presses (after long press)
•
Arc-fault test activation; successful operation of
arc-fault detection should cause a fault condition
(rapid red flashing) until cleared
Table 8: Inverter button functions and indicator meanings (repeat of Table 1)
3
Orientation may vary
Inverter indicator button