HW
Automatic
H2
Automatic
OUMAN EH-203
MITTAUKSET
OUMAN EH-203
OUMAN EH-203
MEASUREMENTS
Labeling
OUMAN EH-203
L1 Valitse
Mittaukset
Säätökäyrien as
Kellotoiminnat
L1 Valitse
Mittaukset
Säätökäyrien as
Kellotoiminnat
L1 Valitse
Mittaukset
Säätökäyrien as
Kellotoiminnat
L1
Ulkol. °C
Menovesi °C
Valinta
Automaattiohj
L1
Ulkol. °C
Menovesi °C
Valinta
Automaattiohj
Press the
button to browse different measurements.
Press
to exit from the measurements display
ESC
Browsing through measurements:
Every sensor has it's own typical range. (Eg. outdoor sensor 50...+ 50 C).
If the sensor's measured value is outside of this range, a - or + character will
appear on the measurements display in place of the sensor's measured
value to indicate whether the value is above or below the range.
If there is a sensor defect the regulator gives an alarm (see p. 18) and "err"
will appear in place of the measured value.
o
Meas. 6
Kylmä vesi
Nimetön mittaus
Name change
Meas. 6
Give new label
Move the cursor to the measurement (6, 9, 10 or 11) that has to be relabeled. Press
OK.
Meas. 9
Meas. 10
Meas. 11
The regulator can be connected to 14 different measurement data at the
same time (11 NTC measur 3 digital inputs).Measurement data can
also be read through the bus. Also the position of the voltage controlled
(0...10V or 2...10V) actuator can be seen. Measurements 6, 9, 10, and 11
can be used to indicate external alarms (additional information on alarms
page 18) ATTENTION!
Only the measurements connected to the
regulator appear on the display.
Relabeling measurements 6, 9, 10 and 11:
8
Name change
Meas. 6
a
Text editor's characters in the order in which they appear:
"Empty” . - numbers 0... 9 letters A ...Z a … z ä ö å
Press the
button to move cursor to "Measurements”. Press
OK.
H1 Select
Heating curve
Settings
Measurements
Info water temp
Press
When you press the
button in the basic display mode, the regulator
displays all the measurement results in turn and then returns to the basic
display mode.
You can also browse measurement data in the "Measurements" display.
ESC
+
until the display no longer changes.
You are then in the "Selection" display shown in the adjoining picture.
OPERATING INSTRUCTION:
Press
OK.
Move the cursor to "Give new label". Press
A letter "a" appears on the display. You can move forward or backward in
the character row by pressing the
or button. Confirm the letter/character
by pressing
, then the same letter/character that you selected will blink in
the next space. The character that has been fed last can be deleted by
pressing
. If you press the
button for a while you can delete the
new name and the previous name remains in effect. When you have
written the name, press
for a while (over 2 sec.), to exit from the data
entry mode and the name that has been written will come into effect.
OK.
+
-
OK
ESC
ESC
OK
H1
Outdoor
°C
SupplyTemp
°C
Selection
Automatic
-15
52
Meas. 6
Meas. 9
Meas. 10:
Meas. 11:
: A free information type temperature measurement which can be labelled (the factory setting is cold water)
or used as a measurement effecting control (H2 room or wind compensation, see special maintenance, p. 30).
A free information type temp. measurement which can be labelled (the factory setting is H2 return water).
A free information type temperature measurement which can be labelled (the factory setting is DH
Return HE3). If relay 1 is reserved for burner control and/or relay 2 is reserved for heating resistor control, the
controller uses meas. 10 as a temp. control measurement.
:
A free information type temperature measurement which can be labelled (the factory setting is DH
Return HE2). If relay 1 is controlled by a temperature controlled relay (see p. 26), the controller automatically
reserves measurement 11 for relay 1 temperature measurement.
KEYWORD:
Measurements
MEASUREMENTS
Swimming
pool
Cellar
Sauna
Accumulator
Measurements
°C
H1 Supply
52
H1 Room
21.2
H1 Ret.water 28
Outdoor
-15
H2 Supply
48
Cold water
5
HW Supply
55
HWcircul.wat 47
H2 Return
103
DH ReturnHE3 34
DH ReturnHE2 30
DH m3 2001584.6
Inst. l/s
66
DH MWh
10035.2
Inst. kW
145.3
Wat m3
11123.5
ActuatorH1
45%
ActuatorH2
45%
ActuatorHW
45%
Measurements
H1
Supply=52/
H1
Room=21.2/
H1
Ret.water=28/
Outdoor=-15/
H2