SECTION 4: INSTALLATION
CAS40P 40 CFM / 100 PSIG
PAGE - 16
®
An Oshkosh Corporation Company
4.4 CONNECTING THE ELECTRICAL
SUPPLY
Refer to
Figures 4-2
and
4-4
. Connect the electrical
supply connector, located at the connection port panel
end of the unit.
4.5 HYDRAULIC SYSTEM
REQUIREMENTS
Refer to
Figure 4-5
for hydraulic system schematic. The
following
requirements
should
be
taken
into
consideration before installing the hydraulic system:
•
The hydraulic flow and pressure requirements of
the air compressor.
•
A continuous hydraulic load is necessary when the
compressor is running.
KEY
DESCRIPTION
KEY
DESCRIPTION
A
HOSE AND CONNECTION SIDE: 10 inches
D
ROOF PANEL ACCESS SIDE: 10 inches
B
INSTRUMENTATION SIDE: 10 inches
E
REAR/COOLER SIDE: 10 inches
C
ROOF PANEL ACCESS DOOR: 24 inches for
hinged door clearance and/or maintenance
F
Additional allotted dimensional/surrounding space (mea-
surements
A
through
E
) of package
must
allow for con-
tinuous circulation of air around and through the machine
for cooling purposes.
DO NOT
install in an enclosed
area.
NOTE:
The dimensions listed above are the minimum required clearance distances needed for properly cooling the machine.
Additional clearance room may be desired for easier access for control and/or maintenance functions.
Figure 4-3: Minimum Clearance Distances Needed for Machine Cooling and Access
Manual #99905382 Rev 02
(JUNE 2018)