SECTION 6: MAINTENANCE
CAS40P 40 CFM / 100 PSIG
PAGE - 38
®
An Oshkosh Corporation Company
To maximize the accessible work space needed for
compressor unit maintenance, both side panels
(drive assembly access panel and instrumentation
panel) must be removed. Consult
Section 6.4.1.2,
Removing and Replacing a Side Panel
to remove
the side panels.
Refer to
Figure 6-7
. If compressor fails to pump air
or seems slow in filling up tank, the valves may need
to be cleaned.
1. Disconnect unit from power source.
Lubrication
6.4.6.2
Service
6.4.6.3
WARNING
Before performing maintenance:
Shut down machine, relieve all system
pressure and lock out all power, as per
the Safety Section of this manual. If
machine is hot, allow package to cool
before removing any panel.
NOTE THAT THE SYSTEM CAN BE
STARTED REMOTELY:
Always clearly tag the start-up
instrumentation against accidental
system start-ups during maintenance.
DANGER
Valves must be reinstalled in original
position. Incorrect valve replacement
may result in overpressure of the
cylinder head resulting in catastrophic
failure, injury or death. Valve gaskets
should be replaced each time valves are
serviced.
IMPORTANT
All valves should be removed from the
cylinder head every two (2) or three (3)
months of operation and examined for
cleanliness and carbon formation (build-
up).
System Component Group
Manual
Section
Manual #99905382 Rev 02
(JUNE 2018)