SECTION 4: INSTALLATION
CAS40P 40 CFM / 100 PSIG
PAGE - 18
®
An Oshkosh Corporation Company
Pressure-rated for 200 psig (minimum)
MOUNTING SPECIFICATIONS
• If tank is to be permanently mounted, IMT
recommends a mounting with no less than four (4)
mounting/securing points
• Tank mounted levelly
• Service air out port of tank readily accessible, or
piped/hosed for such availability
• Drain is readily available, or piped/hosed for such
availability
• Tank drain function must have auto-drain, petcock, or
valve that allows for tank to be purged of moisture
while tank is pressurized/system is running
The above listed features should serve as a minimum
checklist of what to include when installing the reservoir
portion of the compression system. However, if additional
assistance is needed for designing the reservoir tank-
side of the service out operation, consult the IMT Service
Department.
Manual #99905382 Rev 02
(JUNE 2018)