Installation and operating manual for WATERFRIEND -Chlorine MRD-3 Page 31
To adjust this value, the following two options are available:
a) PLUS / MINUS keys
•
By pressing the arrow keys
or
, the value can be
modified stepwise.
•
Press
to store the new setting.
b) Keyboard
The value can also be set directly by using the keyboard on the
right side of the display:
•
enter the desired value
•
Press
to store the new setting.
Factory setting: 5 ml/h Range: 2 to 250 ml/h
Switching the flocculation off or on
Procedure:
Press the
key
1. Select Flocculation settings
2. Select Flocculation OFF or Flocculation ON
The selected setting is stored automatically.
Factory setting: OFF
Venting the flocculation tube
This function makes it possible to vent the flocculant hose with an increased output of1l / h.
Procedure:
Press the
key
1. Select Flocculation settings
2. Select Fill hose 1l/h START or STOP
The maximum duration is limited to 60 seconds. After this time, the pump will automatically turn off. The
remaining time is shown on the display (in seconds).
Settings for the service technician
In the menu Service Functions the dosing control can be configured for the particular application.
Settings for the real time clock
For the built-in real time clock different operating modes can be set.
Automatic Internet time
If the WATERFRIEND has an active Internet connection, the built-in clock can be automatically synchronized
with the Internet.
Procedure:
Press the
key
1. Select Service functions
2. Select time & date
3. Select automatic internet time ON or OFF
Factory setting: automatic internet time ON