Everest Fireplace Installation and Operation Manual
______________________________________________________________________________ 45
6.3.6.3
Installation of a Combustible Mantel Shelf
To install a combustible mantel shelf, refer
to table and figure below. For example, a
mantel shelf with a
6"
or less depth (152
mm)
(C)
must be installed at least
48"
(1219 mm)
(B)
above the bottom of the
fireplace.
Different
mantel
shelf
dimensions are listed in the following
table. However, no combustible mantel
shelf can be installed at less than 48"
(1219 mm) above the bottom of the
fireplace. If the depth of the mantel shelf
is not listed in the table below, add 42"
(1066 mm) to the depth of your mantel
shelf to obtain the safe positioning of your
mantel shelf. For example, for a 9" (229
mm) mantel shelf, the safe positioning
would be 51" (1295 mm) above the
bottom of the fireplace (42" (1066 mm) +
9" (229 mm)).
CLEARANCE
A
84" (2134 mm)
SHELF POSITIONING
B
C
48" (1524 mm)
6" or less (152 mm)
50" (1270 mm)
8" (203 mm)
52" (1321 mm)
10" (254 mm)
54" (1372 mm)
12" (305 mm)