background image

  Everest Fireplace Installation and Operation Manual

 

 

52 ______________________________________________________________________________  

7.6.3

 

INSTALLATION INSTRUCTIONS 

1.

 

Cut and frame the holes in the ceiling, floor and roof where the chimney will pass. Use a plumb 
bob to line up the center of the holes. Make sure that the size of the floor and ceiling holes are 

in accordance with the chimney manufacturer’s instructions.

 

2.

 

From below, install a firestop  (A) supplied by the chimney manufacturer in each ceiling/floor 
separation  through  which  the  chimney  will  pass.  At  the  attic  level,  install  a  radiation  shield 
from above (C). 

3.

 

Follow  the  chimney’s  manufacturers’  instructions  and  place  the  first  chimney  length  on 

the 

fireplace.  For  all  chimneys,  you  must  use  an  anchor  plate  (A)  supplied  by  the  chimney 
manufacturer  before  installing  the  first  chimney  length.  Continue  installing  chimney  lengths 
making sure to lock each length in place.  

4.

 

Every  time  the  chimney  passes  through  a  ceiling  or  a  wall,  install  the  appropriate  firestop. 
When  you  reach  the  desired  height,  install  the  roof  support  (not  illustrated).  (Refer  to 
instructions included with the support). 

5.

 

Then,  put the  roof flashing  (D)  in place  and  seal the joint between  the roof  and  the  flashing 
with roofing pitch. For sloping roofs, place the flashing under the upper shingles and on top of 
the lower shingles. Nail the flashing to the roof, using roofing nails. 

6.

 

Place the storm collar (E) over the flashing, and tighten it with the bolt supplied. Finally, seal 
the joint between the storm collar and the chimney, using silicone caulking. 

7.

 

Install the chimney cap (G). 

8.

 

When a ventilated roof flashing is installed, precautions are to be taken not to caulk or seal the 
ventilating openings. 

 

Содержание Everest OB04015

Страница 1: ...50 rue de Copenhague St Augustin de Desmaures Quebec Canada G3A 2H3 Customer service 418 908 8002 E mail tech sbi international com This manual is available for free download on the manufacturer s web...

Страница 2: ...mbustible materials near it may overheat To reduce the risk of fire follow the installation instructions in this manual exactly Contact local building or fire officials about restrictions and installa...

Страница 3: ...ls That Should Not be Burned 14 3 2 How to Prepare or Buy Good Firewood 14 3 2 1 What is Good Firewood 14 3 2 2 Tree Species 14 3 2 3 Log Length 15 3 2 4 Piece Size 15 3 2 5 How to Dry Firewood 15 3 2...

Страница 4: ...mney Fire 32 PART B INSTALLATION 33 6 Safety Information 33 6 1 Summary of Installation Cautions and Warnings 33 6 2 Regulations Covering Fireplace Installation 34 6 3 Fireplace Installation 34 6 3 1...

Страница 5: ...t 66 APPENDIX 4 Installation of Secondary Air Tubes and Baffle 67 APPENDIX 5 Fire Screen Installation Optional 69 APPENDIX 6 Installing the Fresh Air Intake Kit Optional 70 APPENDIX 7 Optional Heat Di...

Страница 6: ...LS TO START A FIRE IN THIS FIREPLACE KEEP ALL SUCH LIQUIDS OR AEROSOLS WELL AWAY FROM THE FIREPLACE WHILE IT IS IN USE DO NOT STORE FUEL WITHIN HEATER MINIMUM INSTALLATION CLEARANCES BURN ONLY SEASONE...

Страница 7: ...O THE FIREPLACE AS THIS WILL CAUSE THE FIREPLACE TO OVERHEAT CAUTION DO NOT INSTALL IN A MOBILE HOME WARNING DO NOT USE MATERIALS OTHER THAN THOSE LISTED IN THE REPLACEMENT PARTS SECTION DURING INSTAL...

Страница 8: ...aft heat loss factors climate fuel type and other variables The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperatur...

Страница 9: ...ticulate emission standard CSA B415 1 10 Canadian standard safety ULC S610 East west through the door you see the longitudinal sides of the logs north south through the door you see the tips of the lo...

Страница 10: ...Fireplace Installation and Operation Manual 10______________________________________________________________________________ A Fresh air inlet 4 G Hot air gravity outlet 8 H Forced air distribution o...

Страница 11: ...Everest Fireplace Installation and Operation Manual ______________________________________________________________________________11...

Страница 12: ...place may be able to heat the main living areas of your house to an adequate temperature we strongly recommend that you also have a conventional oil gas or electric heating system to provide backup he...

Страница 13: ...e manufacturing process meets the latest air quality requirements regarding VOC reduction or elimination The air tubes are stainless steel which can also be recycled Moulded refractory bricks are main...

Страница 14: ...gions of North America usually have only spruce birch and poplar other low density species to burn and yet they can heat their homes successfully Homeowners with access to both hardwood and softwood f...

Страница 15: ...logs are difficult to ignite because they don t have the sharp edges where the flames first catch Logs as small as 3 75 mm should be split to encourage drying Wood should be split to a range of sizes...

Страница 16: ...ake one or even two years to dry fully especially if the pieces are big firewood dries more quickly when stacked in the open where it is exposed to sun and wind it takes much longer to dry when stacke...

Страница 17: ...ents of the fireplace are conditioned As the paint cures some of the chemicals vaporize The vapors are not poisonous but they do smell bad Fresh paint fumes can also cause false alarms in smoke detect...

Страница 18: ...OWN FIRE The top down fire starting method solves two problems with the conventional method first it does not collapse and smother itself as it burns and second it is not necessary to build up the fir...

Страница 19: ...tive such as when doing housework or cooking and it can be warmer when you are inactive such as when reading or watching television Wood burns best in cycles A cycle starts when a new load of wood is...

Страница 20: ...nd the charcoal will not be smothered by the new load of wood If you were to simply spread the charcoal out the new load will smoulder for a long time before igniting Remove ash first and then rake ch...

Страница 21: ...fire two important things happen First the firing rate slows down to spread the heat energy in the fuel over a longer period of time Second the flow rate of exhaust through the fireplace and flue pipe...

Страница 22: ...lect AUTO mode Select the operating speed of the blower with the left knob The blower will start automatically when the fireplace is warm enough and will shut off automatically when the fireplace is c...

Страница 23: ...o last up to eight hours but don t need intense heat In this case use soft wood species and place the logs compactly in the firebox so the pieces are packed tightly together You will need to fire the...

Страница 24: ...rovide three or four hours of heating than to fully load the firebox for a much longer burn Shorter burn cycles make it easier to match the heat output of the fireplace to the heat demand of the space...

Страница 25: ...after a week or so of use This is normal and can be easily removed when the fireplace is cool by wiping with a damp cloth or paper towel and then drying Never try to clean the glass when the fireplace...

Страница 26: ...al with the firebox Therefore the gasket should be inspected periodically to check for a good seal The gasket seal may be improved with a simple latch mechanism adjustment To adjust 1 Remove the split...

Страница 27: ...important to getting a good seal Place the doors face down on something soft like a cushion of rags or piece of carpet Remove the old gaskets from the door by pulling and prying it out with an old sc...

Страница 28: ...ame E Lift out the glass D and pull off the old gasket Do the same for the other door This is a good time to clean the glass thoroughly 5 1 6 REPLACING THE GLASS GASKET The gasket must be centred on t...

Страница 29: ...mp soft cloth to clean plated surfaces If the paint becomes scratched or damaged you can give your wood fireplace a brand new look by repainting it with heat resistant paint Before painting roughen th...

Страница 30: ...ill form in your chimney It is important therefore to check the build up in your chimney monthly when getting used to the new fireplace until you determine the rate of creosote formation Even if creos...

Страница 31: ...d stiff plastic brushes The brush is forced up and down inside the chimney flue to scrub off the creosote The chimney should be checked regularly for creosote build up Inspection and cleaning of the c...

Страница 32: ...mbly and slide it out of the fireplace You now have access to the chimney 5 2 5 CHIMNEY FIRE Regular chimney maintenance and inspection can prevent chimney fires If you have a chimney fire follow thes...

Страница 33: ...TIONS AND WARNINGS THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED IN ANY OTHER MEDIA OWNER S MANUAL CATALOGUES FLYERS MAGAZINES AN...

Страница 34: ...ublished in any other media owner s manual catalogues flyers magazines and or web sites it is important to refer to it to have a safe and compliant installation In addition you will find information a...

Страница 35: ...m Ceiling 84 in 2 13 m measured from the base of the fireplace Fireplace enclosure Back wall 0 Sides 0 Floor under the fireplace 0 Combustible shelf 48 152 cm measured from the base of the fireplace f...

Страница 36: ...ners must be protected 2 horizontally and 2 vertically E by a sheet metal not supplied for the entire width of the floor protection the sheet metal does not have to cover the rest of the wall between...

Страница 37: ...e must be protected by at least a 4 sheet metal one piece bent and continuous not supplied E for the entire width of the floor protection A floor protection of at least 16 406 mm B for hearth extensio...

Страница 38: ...that the ceramic must be placed on a continuous non combustible panel to prevent burning brand from coming into contact with the floor through cracks or gaps in the ceramic grout Check local code for...

Страница 39: ...D FROM THE BASE OF THE APPLIANCE B Frame the fireplace with vertical studs at the sides of the fireplace running from floor to ceiling Position the studs back from the front edge of the fireplace a sp...

Страница 40: ...f 41 1 8 C Chase width 37 1 2 D Chase depth 25 Framing with gravity air distribution kit installed The framing dimensions are for reference only Framing touching the grills must be made from non combu...

Страница 41: ...oid fresh air duct to be within the standoff and have too sharp pipe angles Smaller dimensions may be obtained depending on pipe size type or run configuration Framing can be made from combustible mat...

Страница 42: ...nts to avoid duct to be within the standoff and have too sharp pipe angles Smaller dimensions may be obtained depending on pipe size type or run configuration Framing can be made from combustible mate...

Страница 43: ...2 1308 mm N 72 3 4 1848 mm The framing configuration is for reference only Values M and N are minimum measurements They may need to be increased to allow the installation of a fresh air intake kit or...

Страница 44: ...ng the facing of the fireplace must be non combustible for the width of the fireplace Non combustible materials such as brick stone or ceramic tiles can protrude in front and be glued to the facing of...

Страница 45: ...el shelf dimensions are listed in the following table However no combustible mantel shelf can be installed at less than 48 1219 mm above the bottom of the fireplace If the depth of the mantel shelf is...

Страница 46: ...ble Mantel Shelf with a forced air distribution kit When a gravity air distribution kit is installed the installation of a combustible shelf is done as mentioned in the previous section in addition to...

Страница 47: ...and its roof The chimney must extend at least 1 m 3 ft above the highest point of contact with the roof and at least 60 cm 2 ft higher than any roof line or obstacle within a horizontal distance of 3...

Страница 48: ...the house such as in a basement in combination with an outside chimney are especially prone to flow reversal 2 The Everest is listed only with chimney systems described in TABLE 2 LISTED CHIMNEYS FOR...

Страница 49: ...n top of the chimney Failure to install a rain cap may cause corrosion problems 10 Cut and frame square holes in all floors ceilings and roof that the chimney will go through to provide a 2 50 mm mini...

Страница 50: ...his separation is to prevent smoke migrating from one chimney to another 7 6 CHIMNEY INSTALLATION INSTRUCTIONS Always refer to the chimney manufacturer s Installation manual to ensure a safe installat...

Страница 51: ...Operation Manual ______________________________________________________________________________51 7 6 2 TYPICAL INSTALLATIONS Direct installation Exterior offset installation Interior offset installat...

Страница 52: ...plate A supplied by the chimney manufacturer before installing the first chimney length Continue installing chimney lengths making sure to lock each length in place 4 Every time the chimney passes th...

Страница 53: ...ual ______________________________________________________________________________53 THE STRUCTURAL INTEGRITY OF THE FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED NOTE THE FLOOR AND WALLS BELOW THE A...

Страница 54: ...aterials For a forward deviation C there must always be a distance of 4 between chimney and combustible material and rear deflection B there should always be a 6 distance between the chimney and combu...

Страница 55: ...essary chimney lengths to achieve the required offset Lock the chimney lengths together according to the chimney manufacturer s instructions In many cases it is recommended to use three 3 12 mm screws...

Страница 56: ...annot be enclosed at the attic level AC Triple wall HS AC Triple wall HSS You can get a kit of four 4 rafter protector AC03510 from your dealer Each rafter is made of 22 GA galvanized steel 10 44 W x...

Страница 57: ...ble wall with the chimney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required Follow the chimney manufacturer s installation instructions In cold cli...

Страница 58: ...t When the chimney offset is used to pass through a wall this support may be used on the wall to support the chimney For offset support installation refer to the instructions provided with the support...

Страница 59: ...ion A on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney a...

Страница 60: ...m in which it is installed Room air is already preheated so it will not chill the fire and its availability is not affected by wind pressures on the house Almost all new houses have enough natural lea...

Страница 61: ...of your Everest wood fireplace you need to install the door overlay See figure below for installation instructions Position the overlays on the door frames and secure them from the inside of the doors...

Страница 62: ...d Operation Manual 62______________________________________________________________________________ APPENDIX 2 BLOWER MAINTENANCE OR REPLACEMENT Open the bottom louver Remove the screw securing the bl...

Страница 63: ...on Manual ______________________________________________________________________________63 Pull gently on the control box and turn it over Unplug the wires Also unplug the wire located on the terminal...

Страница 64: ...Everest Fireplace Installation and Operation Manual 64______________________________________________________________________________ Cut the ty rap and take the blower out...

Страница 65: ...Everest Fireplace Installation and Operation Manual ______________________________________________________________________________65 Wiring diagram...

Страница 66: ...tense heat of the fire will normally cause hairline cracks in the refractory slabs These cracks can be minimized by proper curing as described in First Fires They will not normally diminish the effect...

Страница 67: ...g with the rear tube lean and insert the right end of the secondary air tube into the rear right channel hole Then lift and push the tube towards the right inside the hole in the right channel 2 Align...

Страница 68: ..._________________________ To remove the tubes use the above steps in reverse order The air tubes are identified for placement as follows Model Type of tube Everest fireplace Front 90 holes of 0 109 Mi...

Страница 69: ...tallation and Operation Manual ______________________________________________________________________________69 APPENDIX 5 FIRE SCREEN INSTALLATION OPTIONAL Never leave the fireplace unattended when u...

Страница 70: ...n The outside wall termination E must not be installed o At more than 50 of the total height of the chimney o At more than 10 ft 3 m above the base of the fireplace o At more than 3 ft Below the base...

Страница 71: ...amp C The outside wall termination E must be installed outside of the building For a pipe length less than 20 ft use a 4 pipe diameter For a pipe length of more than 20 ft or having more than two devi...

Страница 72: ...the hole open side down and fasten the register to the wall with screws Place the insulated pipe over the wall termination tube and over the fireplace outside air connector At each end carefully pull...

Страница 73: ...it You can also download this manual at www osburn mfg com The EPA standard states that it is necessary to perform certification testing with any ventilation that is likely to alter the units performa...

Страница 74: ...____ APPENDIX 8 OPTIONAL HOT AIR GRAVITY DISTRIBUTION The kit includes 2 x hot air outlets grilles A and frames B 2 x 90o elbows C 6 x steel brackets D with fastening screws E and self tapping screws...

Страница 75: ...Installation and Operation Manual ______________________________________________________________________________75 DIMENSIONS OF HOT AIR OUTLET FRAME WITH ELBOW DIMENSIONS OF HOT AIR OUTLET DECORATIVE...

Страница 76: ...__________________________________________ The hot air grilles can be installed in the same room as the fireplace or one or both of the grilles can be installed in adjacent or upper rooms Installing t...

Страница 77: ...s on top of the fireplace Then cut and remove the insulation in order to obtain two 8 dia openings Then remove the plates closing up the 8 dia holes inside the fireplace 2 Secure the 6 steel brackets...

Страница 78: ...ombustible materiel and secure to the wall with screws Secure the frames F to the elbows E with 3 self tapping screws each Secure the hot air outlet grilles G to the frames with screws 4 Maintain at l...

Страница 79: ...____________________________________________________________________79 7 When passing through a combustible wall or floor a firestop must be installed at the wall or floor penetration The hole size mu...

Страница 80: ...n will cause the fireplace to overheat 9 Do not use insulated flexible ducts as they may overheat 10 Do not use tees or any other components than the ones specifically listed here 11 All ducts must ex...

Страница 81: ...Everest Fireplace Installation and Operation Manual ______________________________________________________________________________81 APPENDIX 9 EXPLODED DIAGRAM AND PARTS LIST...

Страница 82: ...2 LEFT HANDLE AND LATCH KIT 1 12 SE70001 REPLACEMENT GLASS WITH GASKET 10 5 16 X 12 7 16 2 13 AC06400 3 4 FLAT X 6 BLACK SELF ADHESIVE GLASS GASKET 2 14 PL70000 GLASS RETAINER TRIM 4 15 SE63024 GLASS...

Страница 83: ...1 52 44087 RHEOSTAT NUT 1 53 44080 RHEOSTAT WITH NUT 1 54 PL70113 TERMINAL COVER 1 55 44091 ROCKER SWITCH 2 POSITION MSR 8 1 56 99999 BUILD TO ORDER 1 57 VA1150 THERMODISC F120 10F 1 58 44089 DOUBLE C...

Страница 84: ...any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price...

Отзывы: