Everest Fireplace Installation and Operation Manual
40 ______________________________________________________________________________
Framing
The framing dimensions are for reference only.
If a finishing material is installed inside the
enclosure, its thickness shall be added to the
following measurements.
Chase can be made from combustible
materials
A
: Chase height (84 ")
B
: Framing height to standoff (41 1/8 ")
C
: Chase width (37 1/2 ")
D
: Chase depth (25 ")
Framing with gravity air distribution kit installed
The framing dimensions are for reference only.
Framing touching the grills must be made from
non-combustible materials (dark area). Finishing
material covering the dark framing must be made
from non-combustible materials. See facing
section.
E:
Minimum distance between the grill and the
combustible ceiling (12")
F:
Minimum distance below the grill to non-
combustible stud (20")
F:
Minimum distance between the grill and a non-
combustible shelf (Not shown) (15")
G:
Distance between the framing and the first stud
(3")