VOLUME PEDAL
Note that there are two separate VOLUME PEDAL sockets:
The first is located near to the SWITCH-PEDALBOARD socket.
This is a Digitally controlled Volume Pedal socket and will be very useful to control the instrument
volume when using the LOWER VOLUME feature or while recording your volume changes in SONG
RECORDING (see paragraph).
The second is located near to the SUSTAIN pedal socket. This is an analogue controlled Volume Pedal
and this will control the output level without causing any digital noise.
POWER UP
It is possible to select two different Power Up modes: Default and Last Setting.
The Default mode allows the organ to switch on always with a factory set preset with a nice organ
sound setting.
The Last Setting mode allows the organ to switch on with the last selected panel setting.
Follows these instructions to set the Power Up setting:
1. Press the SET button. All the programmable features of the instrument will start flashing.
2. Press the button related to the Led that is now flashing in the OVERALL PRESET section.
The display now show:
Power Up Mode
Default
3. Set the desired Power Up type on the display using the (/\) and (\/) DATA buttons.
4. To store the new setting, press the SET button.
RESET
If it should be necessary to completely erase the internal RAM memory, a very simple reset feature is
provided.
1. Make sure that the instrument is switched off.
2. Press and hold the top 2 bass sound buttons.
3. Switch On the instrument whilst holding the 2 buttons down.
Do not reset the instrument if is not necessary. All your information will be automatically erased