34
PART X : UPDATING FIRMWARE
10.1 Hardware Requirements
10.2 Preparation
10.3 Updating Firmware
1.
A SynScan hand control with firmware version 3.0 or higher.
2.
A computer running Windows 95 or a later version.
3.
A USB Type-B cable.
1.
Create a new folder in the computer (for example,
C:\SynScan
) to save relevant files.
2.
Download the application package “
SynScan Firmware Loader
” from http://www.skywatcher.
com/
and extract the file “
SynScanFirmwareLoader.exe
” to the above folder.
3.
Download the latest firmware package and extract the “
.SSF
” file to the above folder.
1.
Press and hold the “
0
” and “
8
” keys simultaneously, and then plug in the USB cable. The
hand control will display “
SynScan Update
” on the screen. Release the “
0
” and “
8
” keys.
2.
On the computer, run the
SynScanFirmwareLoader.exe
. An application window is show in
Fig 10.3a.
• Use the “
Browse
” button to load the latest firmware file (“
.SSF
” file)
• Check the “
Enforce database update
” to enforce updating the hand control’s database.
Clear it to let the application determine whether it is necessary to update the database.
• Check the “
Auto-detect COM port
” to let the application detect the proper serial port that
will connect to the SynScan hand control. Clear it to manually choose the COM Port
and select a serial port from the “
COM port
” drop-down list.
Fig. 10.3a