Connection
29
Installing the home-sensor
Do not install the home-sensor set while the power is being supplied. Doing so may
result in injury or damage to equipment.
•
Be sure to install the sensor and shielded plate in the direction shown in the figure. Installing them
in the wrong direction may disable sensor detection or cause the shielded plate to contact the
sensor, resulting in sensor damage.
•
When installing the sensor bracket and shielded plate to the actuator, be sure to use the included
screws.
1. Secure the sensor to the sensor bracket using the included screws (M3×2).
Tightening torque: 0.6 N·m (85 oz-in)
For the
DGM85
,
DGM130
and
DGM200
types, the screw holes are provided on two places (right and left) of
the sensor bracket. The sensor can be installed to either of the screw holes (right or left).
Install it to the position in which an indicating light can be seen.
DGM60
DGM85
,
DGM130
,
DGM200
Screws (M3)
Sensor
Sensor mounting bracket
Screws (M3)
Sensor
Sensor mounting
bracket
2. Secure the bracket and sensor assembly to the gear-reduction mechanism of the actuator using the included
hexagonal socket head screws (M2.5×2).
Tightening torque: 0.5 N·m (71 oz-in)
DGM60
DGM85
,
DGM130
,
DGM200
Hexagonal
socket head
screws (M2.5)
Hexagonal
socket head
screws (M2.5)
Do not use the screw holes (M2.5) for the home-sensor of the actuator for any other purpose.
3. Connect the flexible cable with connector to the sensor.
DGM60
DGM85
,
DGM130
,
DGM200
Connector
Sensor
Connector
Sensor