Connection
30
•
Do not connect or remove the flexible cable with connector while the power is being supplied.
Doing so may cause damage to the sensor.
•
Wire the flexible cable in such a way that it will not contact the actuator.
When removing the flexible cable with connector, pull out the connector while pressing it firmly from
the top and bottom.
4. Secure the shielded plate using the included hexagonal socket head screws (M2.5×2).
Tightening torque: 0.5 N·m (71 oz-in)
For the
DGM60
type, secure the shielded plate to the back side of the load.
For the
DGM85
,
DGM130
and
DGM200
types, secure the shielded plate to the output table.
Load (back side)
DGM60
DGM85
,
DGM130
,
DGM200
Hexagonal socket
head screws (M2.5)
Hexagonal socket
head screws (M2.5)
Shielded plate
5. In the case of the
DGM60
type, secure the load being attached the shielded plate onto the output table.
Machining dimensions of shielded plate for installation (for the
DGM60
type only)
37±0.2
(1.457±0.008)
2×M2.5
Output table center
7 (0.28)
When providing mounting holes on the table
center side [mm (in.)]
62±0.2 (2.441±0.008)
2×M2.5
Output table center
7 (0.28)
When providing mounting holes on the opposite
side of the table center [mm (in.)]
•
The photomicrosensor is designed for use inside equipment and therefore has no special means of
protection against disturbance light. If the actuator is to be used under an incandescent lamp or in
conditions that are subject to disturbances from external light, provide the means to prevent such
interference.
•
Use the product after checking the sensor is installed securely.
•
Place the power cables such as the motor cable or power supply cable as far apart as possible from
the sensor cable. If the power cables and sensor cable have to cross, cross them at a right angle.
•
To prevent sensor deterioration due to temperature, operate the actuator under the following
conditions.
· Actuators equipped with the
AZ
Series:
Ambient operating temperature 0 to +40 °C (+32 to +104 °F), motor surface temperature 80 °C
(176 °F) or lower
· Actuators equipped with the
AR
Series or
RKII
Series:
Ambient operating temperature 0 to +40 °C (+32 to +104 °F), motor surface temperature 90 °C
(194 °F) or lower
•
Adhesion of dust on the sensor may cause actuator malfunction. Clean and/or replace the sensor
regularly.
•
Use a common GND for the sensor power and user’s controller power. Any difference in GND
potential will result in a sensor malfunction.