TECHNICAL MANUAL
BLUE PAPER RISE ·
2021
78 | ORBEA
ORBEA | 79
EN
RECOMMENDED REBOUND SETTINGS
FOX 36 FLOAT
FOX 34 FLOAT
Rider+equipment
weight (Kg)
Rider+equipment
weight (Lb)
36 GRIP
(clicks)
36 GRIP 2
Air pressure
FIT 4
(clicks)
GRIP
(clicks)
LSR (clicks) HSR (clicks)
54-59
120-130
13
9
8
65psi/ 4.5 bar
8
13
59-64
130-140
12
8
7
70psi/ 4.8 bar
8
12
64-68
140-150
11
7
6
74psi/ 5.1 bar
7
11
68-73
150-160
10
7
6
80psi/ 5.5 bar
7
10
73-77
160-170
9
6
5
85psi/ 5.9 bar
6
9
77-82
170-180
8
6
5
90psi/ 6.2 bar
6
8
82-86
180-190
7
5
4
96psi/ 6.6 bar
5
7
86-91
190-200
6
4
3
101psi/ 7.0 bar
5
6
91-95
200-210
5
4
3
106psi/ 7.3 bar
4
5
95-100
210-220
4
3
2
111psi/ 7.6 bar
4
4
100-104
220-230
3
2
1
117psi/ 8.0 bar
3
3
104-109
230-240
2
2
1
122psi/ 8.4 bar
2
2
109-113
240-250
1
1
0
126psi/ 8.7 bar
1
1
SUGGESTED REBOUND SETTINGS
FOR FOX 34 AND 36 FLOAT FORKS
The rebound adjustment depends on the shock air
pressure. The more air pressure, the more closed the
rebound circuit will have to be.
7UG VJG ƂPCN CKT RTGUUWTG QP [QWT UJQEM VQ ƂPF VJG
correct rebound setting. Turn the rebound idal clock-wise
to the fully closed position.
Then count "clicks" as per the table below.
Air pressure (psi)
Recommended rebound
setting (clicks)
<100
Open
100-120
11
120-140
10
140-160
9
160-180
8
180-200
7
200-220
6
220-240
5
240-260
4
260-280
3
280-300
Close
104-109
230-240
109-113
240-250
FOX SHOCKS SETTINGS
4GCFVJGEQORNGVGOCPWCNQHVJG(QZUJQEMUURGEKƂECVGFQP4KUGHTQOVJGOCPWHCEVWTGTUFQEWOGPVCVKQP
FOX DPS AND DPX2 EVOL MANUAL
www.ridefox.com/fox17/help.php?m=bike&id=1079
SUGGESTED AIR PRESSURE SETTINGS
FOR THE FOX DPX EVOL AND DPX2
EVOL SHOCKS
6JG VCDNGU DGNQY IKXG CRRTQZKOCVG XCNWGU 6JG ƂPCN
settings may change depending on riding style and
terrain conditions.
Adjust the shock´s air pressure until the desired SAG is
CEJKGXGF#5#)YKNNIKXG[QWCƂTOGTHGGNKPIYKVJ
more support. A 30% SAG will provide a plusher riding
experience.
Once the desired SAG is achieved, adjust the Rebound
depending on the air pressure of your shock.
7UGVJGƂPCNCKTRTGUUWTGQP[QWTUJQEMVQƂPFVJGTG-
commended Rebound setting on the table below. Turn
the Reboud dial clockwise until the Closed position.
Then count "click" as per the table below counter-clockwise.
You can use the integrated SAG measurement on the
linkage preload tool to measure a 30% SAG.
RECOMMENDED SAG SETTING
30%
REBOUND ADJUSTMENT
Based on air pressure after target SAG is achieved.
Содержание L365