2-24
INSTALLATION
ORBAN MODEL
tals 20%, you can set the total modulation to 110% (
±
82.5 kHz deviation). The
8600Si has the ability to reduce audio modulation to compensate for subcarriers.
The advantage of using the modulation reduction function is that the pilot injec-
tion stays constant when the audio modulation is reduced. However, using the
modulation reduction function is slightly inconvenient because it requires pro-
gramming and activating at least one 8600Si GPI input.
If you have the same sub-
carrier injection at all times
, a more convenient alternative is to set the desired
modulation level by using the
C
OMPOSITE
L
EVEL
control(s). Then turn up the pilot
injection control until the injection equals 9% modulation.
If you wish to use the modulation reduction function anyway:
A)
Navigate to
Setup
>
Next
>
M
ODULATN
R
EDUCTN
.
B)
Hold down the appropriate
M
OD
.
R
EDUCTION
button and turn the knob to set
the amount of modulation reduction produced by the
M
OD
.
R
EDUCTION
1
and
M
OD
.
R
EDUCTION
2
functions.
You can program these to be activated via any rear-panel GPI input or by
the 8600Si’s clock-based automation. (See
starting on page 2-45 and
When both modulation reduction functions are active, the modulation
reduction is the sum of their settings.
To comply with FCC Rules, set the modulation reduction to one-half the
injection of the associated subcarrier. For example, if your subcarrier in-
jection totals 20% from two 10% subcarriers, set
M
ODULATION
R
EDUCTION
1
TO
“5%” and
M
ODULATION
R
EDUCTION
2
to 5%. This will reduce your audio
modulation to 90% (100% – 5% – 5%). When you add back the 20%
modulation due to the subcarriers, you get the required 110% total mod-
ulation.
The Modulation Reduction function is active as long as signal is applied
to its associated GPI input.
C)
Program the GPI input(s).
a)
Navigate to
Setup
>
Next
>
N
ETWORK
&R
EMOTE
>
R
EMOTE
I
NTERFACE
.
b)
Using the
Next
button, scroll the screen until you see the button
corresponding to the GPI terminal you wish to program.
c)
Hold down this button and turn the knob until you see
M
OD
.
R
EDUCTION
1
or
M
OD
.
R
EDUCTION
2
as desired.
To program clock-based automation to activate modulation reduction, follow
the instructions found in “Using Clock-Based Automation” on page 2-39.
3.
Program Silence Sense (optional)
You can program the 8600Si to switch automatically from its digital input to its
analog inputs if the
I
NPUT
S
OURCE
is set
to
D
IGITAL
and the signal at the digital in-
put falls silent. Conversely, you can also program the 8600Si to switch automati-
cally from its analog inputs to its digital input if the
I
NPUT
S
OURCE
is set
to
A
NALOG
and the signal at the analog input falls silent
Содержание OPTIMOD-FM 8600Si
Страница 1: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Страница 7: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Страница 56: ......
Страница 255: ...OPTIMOD FM DIGITAL OPERATION 3 89...
Страница 272: ......
Страница 328: ......
Страница 330: ...6 28 TECHNICAL DATA ORBAN MODEL 8600Si CONTROL BOARD PARTS LOCATOR...
Страница 336: ...6 34 TECHNICAL DATA ORBAN MODEL 8600Si 5700 8600S I O DSP BOARD PARTS LOCATOR DRAWING 32370 860 01...
Страница 341: ...OPTIMOD FM DIGITAL TECHNICAL DATA 6 39 8600S I O BOARD COMPOSITE SCA DAUGHTERBOARD SHEET 4b of 12 62310 000 02 1...
Страница 350: ...6 48 TECHNICAL DATA ORBAN MODEL 8600Si FRONT REAR FRONT PANEL PARTS LOCATOR DIAGRAM 32275 000 09...
Страница 354: ...6 52 TECHNICAL DATA ORBAN MODEL 8600Si...
Страница 355: ...OPTIMOD FM DIGITAL TECHNICAL DATA 6 53...
Страница 356: ...6 54 TECHNICAL DATA ORBAN MODEL 8600Si...