OPTIMOD 6300 DIGITAL
TECHNICAL DATA
6-3
User Bits:
Unit can pass AES3 User Bits from its AES input to AES Output #1.
Sampling Rate:
32, 44.1, 48, 88.2, or 96 kHz, automatically selected.
Connector:
XLR-type, female, EMI-suppressed. Pin 1 chassis ground, pins 2 and 3 trans-
former balanced and floating, 110
impedance.
Input Reference Level
: Variable within the range of –30 dBfs to –10 dBfs.
J.17 Deemphasis:
Software-selectable.
Filtering:
RFI filtered.
Digital Audio Outputs (x2)
Configuration:
Stereo or Two-Channel per AES3 standard. Output configured in software
as flat or pre-emphasized to the chosen processing preemphasis (50
µ
s or 75
µ
s), with or
without J.17 preemphasis.
Sample Rate:
Internal free running at 32, 44.1, 48, 88.1 or 96 kHz, selected in software.
Can also be synced to the AES3 digital, AES11id, or Wordclock input at 32, 44.1, 48,
88.1 or 96 kHz, as configured in software. (Passband is limited to approximately 14.7
kHz when using 32 kHz output sample rate.)
Word Length:
Software selected for 24, 20, 18, 16 or 14-bit resolution. First-order highpass
noise-shaped dither can be optionally added, Dither level automatically adjusted appro-
priately for the word length.
Connector:
XLR-type, male, EMI-suppressed. Pin 1 chassis ground, pins 2 and 3 trans-
former balanced and floating, 110
impedance.
Output Level
(100% peak modulation): –20.0 to 0.0 dBfs software controlled.
Filtering:
RFI filtered.
Sync Input
Configuration:
Can accept wordclock or AES11id (75
) sync, selectable in software.
Connector:
Female BNC.
Termination:
Unterminated. For wordclock, use an external 75
terminator if the 6300 is
the last item in the chain. For AES11id, always use a 75
terminator.
Remote Computer Interface
Configuration:
TCP/IP protocol via direct cable connect, modem, or Ethernet interface.
Modem is not supplied.
Serial Port:
115 kbps RS–232 port DB–9 male, EMI-suppressed.
Ethernet Port:
100 Mbit / sec on RJ45 female connector.
Remote Control (GPI) Interface
Configuration:
Eight (8) inputs, opto-isolated and floating.
Voltage:
6–15V AC or DC, momentary or continuous. 12 VDC provided to facilitate use with
contact closure.
Connector:
DB–25 male, EMI-suppressed.
Control:
User-programmable for any eight of user presets, factory presets, bypass, test
tone, stereo or mono modes, analog input, digital input.
Filtering:
RFI filtered.
Tally Outputs
Circuit Configuration:
Two NPN open-collector outputs.
Содержание OPTIMOD 6300
Страница 1: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Страница 7: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Страница 22: ......
Страница 48: ......
Страница 94: ...2 46 INSTALLATION ORBAN MODEL 6300 ...
Страница 118: ......
Страница 200: ......
Страница 214: ......
Страница 236: ...6 22 TECHNICAL DATA ORBAN MODEL 6300 CONTROL BOARD PARTS LOCATOR ...
Страница 242: ...6 28 TECHNICAL DATA ORBAN MODEL 6300 I O DSP BOARD PARTS LOCATOR ...
Страница 252: ...6 38 TECHNICAL DATA ORBAN MODEL 6300 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM ...
Страница 255: ...OPTIMOD 6300 DIGITAL TECHNICAL DATA 6 41 ...