4-8
MAINTENANCE
ORBAN MODEL 6300
g)
Navigate to
S
ETUP
and set controls as follows. Scroll the display by using
the
N
EXT
and
P
REV
buttons access the following controls:
PRE-E...................................................................................................Flat
AGC PRE-E ..........................................................................................Flat
MB PRE-E ............................................................................................Flat
2.
Test the power supply
The power supply is a module. In case of any power supply failure, the entire
supply must be replaced by an exact replacement (available from Orban Service).
Attempts to repair the supply on a component level and/or to replace the supply
with a non-approved supply may compromise your Optimod’s compliance with
the EMI and safety regulations in your country.
The +3.3V and +2.5V supplies are locally regulated on the DSP and con-
trol boards (see Section 6).
Measure the power supply’s regulated voltages at the DVM and observe the rip-
ple with an oscilloscope, AC-coupled. Convenient sources of these voltages are
the inductors adjacent to power supply connectors on the I/O+DSP board. Con-
nect your probe to the sides of the inductors away from the power supply con-
nectors. The results in Table 4-1 are typical.
Power Supply Rail
DC Voltage (volts)
AC Ripple (mV p-p)
+15VDC
+15
0.5
<20
–15VDC
–15
0.5
<20
+5VDC
+5
0.25
<20
Table 4-1: Typical Power Supply Voltages and AC Ripple
3.
Adjust Analog Output Level Trim.
A)
Verify 6300 software controls are set to their default settings. [Refer to step
(1.A) on page 4-7.]
B)
Feed the 6300 output with the built-in 400 Hz test tone:
a)
Navigate to
S
ETUP
>
T
EST
.
b)
Set the
M
ODE
to
T
ONE
.
C)
Connect the audio voltmeter to the Left Analog Output.
D)
Adjust output trim VR200 to make the meter read +10.0 dBu. (0 dBu = 0.775V
rms.) Verify a frequency reading of 400 Hz.
E)
Verify THD+N reading of <0.05% (0.02% typical) using a 22 kHz low pass filter
in the distortion analyzer.
F)
Set the
M
ODE
to
B
YPASS
.
B
YPASS
defeats all compression, limiting, and program equalization but
retains preemphasis.
G)
Verify a reading (noise) of <–80 dBu at the output of the unit.
Содержание OPTIMOD 6300
Страница 1: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Страница 7: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Страница 22: ......
Страница 48: ......
Страница 94: ...2 46 INSTALLATION ORBAN MODEL 6300 ...
Страница 118: ......
Страница 200: ......
Страница 214: ......
Страница 236: ...6 22 TECHNICAL DATA ORBAN MODEL 6300 CONTROL BOARD PARTS LOCATOR ...
Страница 242: ...6 28 TECHNICAL DATA ORBAN MODEL 6300 I O DSP BOARD PARTS LOCATOR ...
Страница 252: ...6 38 TECHNICAL DATA ORBAN MODEL 6300 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM ...
Страница 255: ...OPTIMOD 6300 DIGITAL TECHNICAL DATA 6 41 ...