In the online menus of the OC Remote software and OPTI-
CODEC 7400 the following messages may be displayed:
When the OPTICODEC is in standby mode, you can select
from the main menu the following functions by entering
certain number codes:
Audio loop without encoder/decoder.
By pressing the ‘Enter’ key you can change the audio in-
put to AES/EBU or S/PDIF. By pressing 1, 2 or 3 you can
change the sampling frequency.
By pressing HANG up, you leave the audio test.
By simultaneous operation of the keys 1+2+3 all LEDs on
the keypad light up.
Interrogation of the OC 7400 software versions.
By pressing 3+6+9 simultaneously, reset will be started.
Number Codes
Audio Test (8+8+8+8+8)
LED Test (1+2+3)
9+9+9+9+9
Reset (3+6+9)
OPTICODEC
Status Messages / Number Codes in Standby Mode
Status Messages
• NO X.21 CLOCK
• ILLEGAL X.21 CLK
• NO INPUT SIGNAL
• DSP TIMEOUT
• ISDN PIPELINE
OVERFLOW
• REMOTE PIPELINE
OWERFLOW
Possible Cause
No X.21 clock was determined.
The measured X.21 clock does not correspond to a
ISO data rate.
The AES or SPDIF input has been set and there is
no signal at the selected input.
On access to the DSPs there is no confirmation
message.
ISDN operation is not possible.
The remote port does not respond.