70
E
OPTICODEC
OPTICODEC 7400
System Setup
To achieve the highest possible transmission reliability with
a low delay, it should be ensured that no further units are
simultaneous transmitting data within the network.
Here the port number for audio transmission is entered.
Always enter the value 6136 for the OPTICODEC.
This encoder configuration is taken over when the OPTI-
CODEC is called by another OPTICODEC in the mode
Point-to-Point. It may be possible to use: For Tx Layer 2,
384 kbps, 48 kHz, dual mono; for Rx Layer 3, 32 kbps, 16
kHz, mono. As opposed to the corresponding menu to call
via ISDN, here no automation is possible.
Dialing Attempts
This menu item serves for setting the desired dialing
attempts. You can select between 1 ... 5 and INFINITE.
Dialing Delay
This menu items serves for setting the desired time between
dialing attempts (between 10 and 360 seconds).
Redialing Attempts
This menu item serves for setting the desired redialing
attempts, if a connection had not been disconnected by
the calling OPTICODEC. You can select between 0 ... 9
and INFINITE.
Not all data transmission applications have the same priority
and not all of these require the same high standards for
the transfer of data. In order to minimize or avoid the risk
of data network congestion, a so-called „Quality of Service“
of QoS option has been implemented in the IP header with
acknowledgement fields such as Time to Live, Protocol and
Header Checksum.
Port
Accept Configuration
Audio Data Encoder
Dialing
Quality of Service