D-16
External I/O Expansion Unit for SPARC Enterprise M
x
000 Servers Installation and Service Manual • April 2011
2. The following FMRIs indicate failure of a boat location signal:
■
hc:///iox=
box_instance
/boat_loc=x
■
hc:///iox=
box_instance
/iob=x/loc_sig=0
Two I/O boats were reported to be in the same location in a chassis. Try testing
each I/O boat separately and examine if the reported location of the I/O boat is
correct. Try an I/O boat that is valid and working in each bay of a chassis to
determine if failure is contained in the chassis.
D.2.6.2
Boat Not Monitored
Possible Causes
■
The I/O boats are connected to two different systems.
■
I
2
C component access errors prevent detection of both I/O boats.
■
Corrupted FRUID contents in the centerplane chassis prevent the firmware from
identifying the correct External I/O Expansion Unit chassis.
Resolution
1. Verify that both I/O boats are connected to the same server.
The I/O boats can be configured into different domains on the same server, but
the boats must be managed by the same service processor (XSCF). Otherwise, both
systems might attempt to update the same FRUID data causing data corruption of
FRUID records in the centerplane and PSUs.
2. Inspect the host system to see which add-in slots contain link cards.
Verify that software correctly detects the link cards. If a link card is present and
powered on, but it is not seen by software, there might be problems with the I
2
C
bus going to this slot. Replace the link card or move the link card to a different
slot.
Note –
If an I/O boat is present, but the External I/O Expansion Unit is not
displayed as a 4-character value when listed by
ioxadm
, the software could not read
the serial number from the centerplane.
The box identifier would look something like
IOX@?0
.
3. If no other I
2
C errors are present, replace the chassis.
MSGID IOXSCF-8000-U4 fault.chassis.iox.env.config
Содержание SPARC Enterprise M4000
Страница 4: ......
Страница 10: ...x External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 14: ...xiv External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 58: ...1 44 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 78: ...2 20 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 136: ...A 6 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 156: ...C 14 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 178: ...D 22 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 182: ...Index 4 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...