This is typical output of the
prtdiag
command
pcie3 etherne/hp connected configured ok
pcie4 fibre/hp connected configured ok
pcie5 fibre/hp connected configured ok
pcie6 fibre/hp connected configured ok
EXAMPLE C-3
Typical
prtdiag
Output
#
prtdiag
System Configuration: Sun Microsystems sun4u Sun SPARC Enterprise (FF2) Server
System clock frequency: 1012 MHz
Memory size: 8192 Megabytes
==================================== CPUs ====================================
CPU CPU Run L2$ CPU CPU
LSB Chip ID MHz MB Impl. Mask
--- ---- -------------------- ---- --- ----- ----
00 0 0, 1, 2, 3 2150 4.0 6 129
00 1 8, 9, 10, 11 2150 4.0 6 129
====================== Memory Configuration ======================
Memory Available Memory DIMM Number of
LSB Group Size Status Size DIMMs
--- ------ ------------ ------- ----- ---------
00 A 4096MB okay 1024MB 4
00 B 4096MB okay 1024MB 4
========================= IO Cards =========================
LSB Name Model
--- -------------- ------------
00 scsi LSI,1064
00 network N/A
00 network N/A
00 pci0,0 N/A
00 network SUNW,pcie-no
00 network SUNW,pcie-no
EXAMPLE C-2
Typical Output of the
cfgadm
Command
(2 of 2)
Содержание SPARC Enterprise M4000
Страница 4: ......
Страница 10: ...x External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 14: ...xiv External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 58: ...1 44 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 78: ...2 20 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 136: ...A 6 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 156: ...C 14 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 178: ...D 22 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 182: ...Index 4 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...