Caution –
If you install a PCI card when the External I/O Expansion Unit is
running, be prepared to complete the installation within two minutes or so. If you
leave a carrier slot empty, the External I/O Expansion Unit might overheat.
New carriers include dummy cards. The dummy cards help the carriers to stay in
place and to control the passage of air through the I/O boat. For information about
dummy cards, see
Section 1.2.1.2, “Dummy Cards” on page 1-11
1.2.1.1
Carrier Slots
There are seven carriers in each I/O boat (
). Carriers can be adjusted to fit
various sizes and shapes of PCI cards. Link cards use the same type of carrier.
■
Carrier slot 0 is always used for the link card.
■
Carrier slots 1 through 6 are used for PCI cards.
FIGURE 1-6
PCI Carrier
Figure Legend
1
Carrier handle
2
Carrier locking screw
Содержание SPARC Enterprise M4000
Страница 4: ......
Страница 10: ...x External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 14: ...xiv External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 58: ...1 44 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 78: ...2 20 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 136: ...A 6 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 156: ...C 14 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 178: ...D 22 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...
Страница 182: ...Index 4 External I O Expansion Unit for SPARC Enterprise Mx000 Servers Installation and Service Manual April 2011 ...