background image

Netra Server X3-2
(formerly Sun Netra X4270 M3 Server)

Installation Guide

Part No.: E27127-04
May 2013

Содержание Netra Server X3-2

Страница 1: ...Netra Server X3 2 formerly Sun Netra X4270 M3 Server Installation Guide Part No E27127 04 May 2013 ...

Страница 2: ...s sont concédés sous licence et soumis à des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer exécuter publier ou afficher le logiciel même partiellement sous quelque forme et par quelque procédé que ce soit Par ailleurs il est interdit de pr...

Страница 3: ...ications 9 Physical Specifications 10 Minimum Clearance for Service Access 10 AC and DC Power Supply Specifications 11 Input Power Information 12 Overcurrent Protection Requirements 13 DC Power Source Power Connection and Grounding Requirements 14 Environmental Requirements 15 Acoustic Noise Emissions 16 Airflow Clearance 16 Preparing for Installation 19 Shipping Kit Inventory 19 Handling Precauti...

Страница 4: ...19 Inch Sliding Rail Kit 34 Installing the 600 mm Hardmount Kit 4 Post Rack 40 600 mm Hardmount Kit 4 Post Rack 41 Install the Server 4 Post 600 mm Hardmount Kit 42 Installing the Server in a 2 Post Rack 51 Installing the 19 Inch Hardmount Kit 2 Post Rack 51 19 Inch Hardmount Rack Kit 2 Post Rack 52 Install the Server 2 Post 19 Inch Hardmount Rack Kit 53 Installing the 19 Inch Sliding Rail Kit 2 P...

Страница 5: ... NET MGT Port 84 Gigabit Ethernet Ports 84 USB Ports 86 Video Port 86 Alarm Port 88 Powering On the Server the First Time 91 Connect AC Power Cords 92 Assembling DC Power Cords and Applying DC Power 93 Connect the Chassis Ground Wire 94 Assemble the DC Input Power Cord 95 Install Strain Relief Housings 99 Connect DC Power Cords 102 Power On the Host for the First Time 103 Glossary 107 Index 115 ...

Страница 6: ...vi Netra Server X3 2 Installation Guide May 2013 ...

Страница 7: ...nicians system administrators and authorized service providers These topics are covered Product Notes on page vii Related Documentation on page viii Feedback on page viii Support and Accessibility on page viii Product Notes For late breaking information and known issues about this product refer to the product notes at http www oracle com pls topic lookup ctx NetraServerX3 2 ...

Страница 8: ...racle Integrated Lights Out Manager Oracle ILOM 3 1 software library http www oracle com pls topic lookup ctx ilom31 Oracle Solaris OS and systems software library http www oracle com technetwork indexes documentation sys_sw Oracle Linux http linux oracle com documentation Description Links Access electronic support through My Oracle Support http support oracle com For hearing impaired http www or...

Страница 9: ... Front Panel Components Installation on page 5 Rear Panel Components Installation on page 7 Related Information Confirming Server and Site Specifications on page 9 Preparing for Installation on page 19 Installing the Server in a 4 Post Rack on page 27 Installing the Server in a 2 Post Rack on page 51 Connecting Cables on page 77 Powering On the Server the First Time on page 91 ...

Страница 10: ...ications and the site requirements Confirming Server and Site Specifications on page 9 4 Confirm that you received all the items you ordered Shipping Kit Inventory on page 19 5 Review safety and ESD precautions Handling Precautions on page 20 ESD Precautions on page 21 6 Gather the required tools Tools Needed for Installation on page 22 7 Install any optional components that you ordered Optional C...

Страница 11: ...alled memory varies based on what was ordered Storage Depending on the model one of the following configurations Up to 6 2 5 inch hot swappable SAS drives and 1 SATA DVD RW shown Up to 8 2 5 inch hot swappable SAS drives not shown Note The total number of drives and storage capacity varies based on what was ordered with a maximum capacity of either 6 or 8 600 GB drives Optical media Only available...

Страница 12: ...ms Ethernet ports Four 10Gb s Ethernet ports with integrated link speed LEDs Supports 100 Mb s 1000 Mb sec 10000 Mb sec transfer rates PCIe slots Six PCIe Gen3 slots with x8 electrical interface that accommodate low profile PCIe cards USB2 0 ports 6 ports 2 front 2 rear 2 internal Note 1 internal USB port is preinstalled with a USB drive containing OSA Indicators and switches Power button switch L...

Страница 13: ...cators and switches top to bottom Status indicators Locator LED and button Service Required LED System OK LED Power button SP LED Rear PS LED Telco alarm indicators Critical LED Major LED Minor LED User LED Server Service interpreting diagnostic LEDs 2 8 SAS drive slots Server Service servicing drives 3 2 USB 2 0 connectors USB Ports on page 86 ...

Страница 14: ...bottom Status indicators Locator LED and button Service Required LED System OK LED Power button SP LED Rear PS LED Telco alarm indicators Critical LED Major LED Minor LED User LED Server Service interpreting diagnostic LEDs 2 DVD Server Service servicing the DVD 3 2 USB 2 0 connectors USB Ports on page 86 4 8 SAS drive slots Server Service servicing drives ...

Страница 15: ...ription Links 1 Two hot swappable power supplies AC or DC top to bottom PS1 PS0 Server Service servicing power supplies 2 6 PCIe low profile card slots Server Service servicing PCIe cards 3 Chassis ground posts Connect the Chassis Ground Wire on page 94 4 Status indicators Locator LED and button Service Required LED System OK LED Server Service identifying diagnostic LEDs 5 2 USB 2 0 ports USB Por...

Страница 16: ...ry use during installation or service procedures and has a maximum cable length limit of 6 meters Video Port on page 86 7 SP SER MGT port SER MGT Port on page 83 8 SP NET MGT port NET MGT Port on page 84 9 Alarm port DB 15 connector Alarm Port on page 88 10 Not supported on this product Do not connect any cables to these ports 11 4 Gigabit Ethernet ports left to right NET 3 NET 2 NET 1 NET 0 Gigab...

Страница 17: ...rent Protection Requirements on page 13 DC Power Source Power Connection and Grounding Requirements on page 14 Environmental Requirements on page 15 Acoustic Noise Emissions on page 16 Airflow Clearance on page 16 Related Information Understanding the Server on page 1 Preparing for Installation on page 19 Installing the Server in a 4 Post Rack on page 27 Installing the Server in a 2 Post Rack on p...

Страница 18: ...e 14 Environmental Requirements on page 15 Acoustic Noise Emissions on page 16 Airflow Clearance on page 16 Minimum Clearance for Service Access Related Information Physical Specifications on page 10 Description U S Metric Height 3 44 in 87 4 mm Width 17 52 in 445 mm Depth from bezel to rear I O 19 74 in 501 mm Weight fully configured without PCIe cards Weight specifications vary based on the mode...

Страница 19: ...ted Information Physical Specifications on page 10 Minimum Clearance for Service Access on page 10 Input Power Information on page 12 Overcurrent Protection Requirements on page 13 DC Power Source Power Connection and Grounding Requirements on page 14 Environmental Requirements on page 15 Acoustic Noise Emissions on page 16 Airflow Clearance on page 16 Parameter AC DC Voltage nominal 100 to 120 20...

Страница 20: ...re an additional surge protector for the AC power configurations if the facility has a surge protector that limits voltage surges to less than 2000V You can however install a surge protector if your site requires an additional protector Note Safety agency requirements prohibit Oracle Corporation from changing a product from AC input to DC input or from DC input to AC input after the product has be...

Страница 21: ...stallation of this product As a general guideline overcurrent protection devices should be rated at a minimum of 125 of the product input current rating in order to provide reliable power under high temperature and transient voltage disturbance conditions However you must consider the characteristics of the protection device and the applicable electrical codes when selecting the rating of a protec...

Страница 22: ...t to the equipment The DC battery power source must be in the same premises as the server The server cannot be in one building with the power source in another building Suitable conductor material Use copper conductors only Power supply connections through the input connector 12 AWG between the server and the source There are three conductors 48V or 60V negative terminal might be marked with a min...

Страница 23: ... page 10 Minimum Clearance for Service Access on page 10 Specification Operating Nonoperating Ambient temperature Does not apply to removable media devices Maximum 41 F to 104 F 5 C to 40 C up to 6000 feet 1829 meters Optimal 69 8 F to 73 4 F 21 C to 23 C Short term maximum 23 F to 131 F 5 C to 55 C Maximum ambient operating temperature is derated by 1 degree C per 500m elevation 40 F to 158 F 40 ...

Страница 24: ...s Related Information Physical Specifications on page 10 Minimum Clearance for Service Access on page 10 AC and DC Power Supply Specifications on page 11 Input Power Information on page 12 Overcurrent Protection Requirements on page 13 DC Power Source Power Connection and Grounding Requirements on page 14 Environmental Requirements on page 15 Airflow Clearance on page 16 Airflow Clearance Note Pro...

Страница 25: ...5 mm clearance at the front of the system and 3 1 in 80 mm at the rear of the server when mounted These clearance values are based on the preceding inlet and exhaust impedance available open area and assume a uniform distribution of the open area across the inlet and exhaust areas Clearance values greater than these are recommended for improved cooling performance Note Be mindful that the combinat...

Страница 26: ...18 Netra Server X3 2 Installation Guide May 2013 ...

Страница 27: ...te Specifications on page 9 Installing the Server in a 4 Post Rack on page 27 Installing the Server in a 2 Post Rack on page 51 Connecting Cables on page 77 Powering On the Server the First Time on page 91 Shipping Kit Inventory Standard system components are installed at the factory Options such as a PCIe2 cards or a monitor are shipped separately Note Inspect the shipping cartons for evidence of...

Страница 28: ...at were ordered with the server Related Information Handling Precautions on page 20 ESD Precautions on page 21 Tools Needed for Installation on page 22 Optional Components on page 22 Rack Cautions on page 23 Stabilize the Rack on page 24 Handling Precautions Caution Deploy the antitilt bar on the equipment rack before beginning an installation Caution The server is heavy Two people are required to...

Страница 29: ...trap foot strap or equivalent safety equipment to prevent ESD when you install or service the server Caution To protect electronic components from electrostatic damage which can permanently disable the server or require repair by service technicians place components on an antistatic surface such as an antistatic discharge mat an antistatic bag or a disposable antistatic mat Wear an antistatic grou...

Страница 30: ...to the SER MGT port Related Information Shipping Kit Inventory on page 19 Handling Precautions on page 20 ESD Precautions on page 21 Optional Components on page 22 Rack Cautions on page 23 Stabilize the Rack on page 24 Optional Components Optional components such as additional memory or PCIe2 cards that were ordered as part of the system are installed in the server at the factory before the server...

Страница 31: ...ssembly the operating ambient temperature of the rack environment might be greater than room ambient temperature Therefore install the equipment only in an environment compatible with the Tma specified for the server Caution Reduced Air Flow Install the equipment in a rack so that the amount of air flow is adequate for the safe operation of the equipment Caution Mechanical Loading Mount the equipm...

Страница 32: ...e the Rack Caution To reduce the risk of personal injury stabilize the rack cabinet and extend all antitilt devices before installing the server Refer to your rack documentation for detailed instructions for the following steps Note In this document the term rack means either an open rack or a closed cabinet 1 Open and remove the front and rear doors from the rack cabinet 2 To prevent the rack cab...

Страница 33: ... cabinet Netra Server X3 2 formerly Sun Netra X4270 M3 Server Safety and Compliance Guide Shipping Kit Inventory on page 19 Handling Precautions on page 20 ESD Precautions on page 21 Tools Needed for Installation on page 22 Optional Components on page 22 Rack Cautions on page 23 ...

Страница 34: ...26 Netra Server X3 2 Installation Guide May 2013 ...

Страница 35: ...er in a 2 Post Rack on page 51 Connecting Cables on page 77 Powering On the Server the First Time on page 91 Step Description Links 1 Install optional components Optional Components on page 22 2 Review cautions Handling Precautions on page 20 3 Stabilize the rack Stabilize the Rack on page 24 4 Install the server in a 4 post rack Installing the Standard 19 Inch Hardmount Kit 4 Post Rack on page 28...

Страница 36: ... provide installation instructions for the 19 inch 4 post hardmount kit that ships with the server 19 Inch Hardmount Kit 4 Post Rack on page 29 Install the Server 4 Post 19 Inch Hardmount Kit on page 30 Related Information Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 ...

Страница 37: ...formation Install the Server 4 Post 19 Inch Hardmount Kit on page 30 Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 No Description 1 Rear mount flanges 2 2 Screws see following table 3 Rear mount support brackets 2 4 Hardmount brackets 2 ...

Страница 38: ...1 Gather the required tools See Tools Needed for Installation on page 22 2 Read the server cautions See Handling Precautions on page 20 and ESD Precautions on page 21 3 Read the rack cautions and stabilize the rack See Rack Cautions on page 23 and Stabilize the Rack on page 24 4 Use four of the supplied M5 x 4 5 mm flathead Phillips screws to secure each of the hardmount brackets to the sides of t...

Страница 39: ...o three of the supplied M4 x 0 5 x 5 mm panhead Phillips screws for each bracket depending on the rack depth 7 Lift the server to the desired location in the rack 8 Using two screws per side secure the front of the hardmount brackets that are attached to the sides of the server 9 Using two screws for each rear mount support bracket secure the rear mount support brackets to the rear of the rack ...

Страница 40: ...eded for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 Installing the 19 Inch Sliding Rail Kit 4 Post Rack Use these topics to install the server using this optional 19 inch sliding rail kit 19 Inch Sliding Rail Kit 4 Post Rack on page 33 Install the Server 4 Post 19 Inch Sliding Rail Kit on page 34 Related Information Tools Needed for Installation on page 22 ...

Страница 41: ...h Sliding Rail Kit 4 Post Rack You also need the hardmount brackets from the standard rackmount kit that came with the server See 19 Inch Hardmount Kit 4 Post Rack on page 29 TABLE 19 Inch Sliding Rail Kit Contents No Description 1 Short brackets 2 2 Extension brackets 2 3 Threaded strips M6 4 and 10 32 4 ...

Страница 42: ...ackets 2 TABLE 19 Inch Sliding Rail Screws Quantity Description Where Used 10 M4 x 0 5 mm x 5 mm Phillips panhead screws 8 for glides 2 extra 10 M6 brass collar screws 4 for short brackets 4 for long brackets 2 extra 8 M5 panhead screws nuts plain washers and star washers 8 for slides 10 M5 x 12 7 mm screws 10 for rack if appropriate 12 M6 x 13 mm screws 10 for rack if appropriate 9 M6 square clip...

Страница 43: ...dmount brackets and M5 x 4 5 mm flathead Phillips screws from the standard rack kit These hardmount brackets and screws are shipped with the standard server shipping kit not as part of the 4 post 19 inch sliding rail kit See 19 Inch Hardmount Kit 4 Post Rack on page 29 5 Use four of the supplied M5 x 4 5 mm flathead Phillips screws to secure each of the hardmount brackets to the sides of the serve...

Страница 44: ... Installation Guide May 2013 8 Using eight of the M4 x 0 5 x 5 mm panhead Phillips screws from the rackmount kit four for each side screw each glide to the side of the server chassis No Description 1 Glide 2 Button 3 Slide ...

Страница 45: ... uprights Use two of the brass M6 collar screws and M6 cage nuts if required and one threaded strip to secure each bracket 11 Lift each long bracket to the desired position at the rear of the rack and attach a long bracket to each of the rear rack uprights To secure each bracket use two of the brass M6 collar screws and M6 cage nuts if required and one threaded strip exactly as you did for the fro...

Страница 46: ...ts instead of the long brackets if the dimension is greater than 665 mm 14 Repeat Step 12 and Step 13 for the slide on the other side of the rack 15 Push the slides completely into the assembly on each side of the rack and release the stop catches 16 Align the glides attached to the server with the slide assemblies in the rack You might find that there is too much or too little room between the tw...

Страница 47: ... outward to the appropriate points then tighten them again 17 Push in the slide buttons and slide the server all the way into the rack enclosure 18 Using two screws per side secure the front of the hardmount brackets that are attached to the sides of the server to the front of the rack The size of the screws varies depending on your particular rack ...

Страница 48: ...ion on page 22 Handling Precautions on page 20 Rack Cautions on page 23 Installing the 600 mm Hardmount Kit 4 Post Rack Use these topics to install the server using the optional 600mm hardmount kit 600 mm Hardmount Kit 4 Post Rack on page 41 Install the Server 4 Post 600 mm Hardmount Kit on page 42 Related Information Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Ca...

Страница 49: ...Installing the Server in a 4 Post Rack 41 600 mm Hardmount Kit 4 Post Rack TABLE 600 mm 4 Post Hardmount Kit Contents No Description 1 Adjustable rails 2 2 Screws 3 Side rails 2 4 Rear flanges 2 ...

Страница 50: ...tion on page 22 2 Read the server cautions See Handling Precautions on page 20 and ESD Precautions on page 21 3 Read the rack cautions and stabilize the rack See Rack Cautions on page 23 and Stabilize the Rack on page 24 4 Get the adjustable rails from the rack kit See 600 mm Hardmount Kit 4 Post Rack on page 41 TABLE 600 mm 4 Post Hardmount Screws Quantity Description Where Used 12 M5 x 7 SEM scr...

Страница 51: ...the middle of each adjustable rail so that you can extend the adjustable rail 6 Lift one of the adjustable rails to the desired location in the rack Using two screws secure the front of the rail in the rack The size of the screws varies depending on your particular rack ...

Страница 52: ...Netra Server X3 2 Installation Guide May 2013 7 At the rear of the rack use two screws to secure the rear of the adjustable rails to the rack The size of the screws varies depending on your particular rack ...

Страница 53: ...ther adjustable rail into the rack 10 Get the rear flanges from the rack kit 11 Using one M5 x 7 SEM screw for each rear flange loosely install the rear flange onto the rear of each of the adjustable rails Do not completely secure the rear flanges to the adjustable rails You will use these flanges to set the rack depth for the server in a later step ...

Страница 54: ...eight of the M5 x 7 SEM screws four for each side rail secure the side rails to the sides of the server The side rails can accommodate rack rail setbacks the distance from the front of the rack to the rack rail of 50 mm 75 mm or 100 mm depending on the type of rack you are installing the server into ...

Страница 55: ...Installing the Server in a 4 Post Rack 47 14 Lift the server into the rack and slide the server onto the adjustable rails ...

Страница 56: ...est flush against the rear of the server 16 Lift the server out of the rack 17 Set the rear flanges to the desired depth in the rack then tighten the single M5 x 7 SEM screw on each of the flanges to secure them to the adjustable rails 18 Lift the server into the rack and slide it onto the adjustable rails 19 Push the server backward until it rests flush against the rear flanges then use one M5 x ...

Страница 57: ...er in a 4 Post Rack 49 20 At the front of the rack use two screws per side to secure the side rails that are attached to the server to the front of the rack The size of the screws varies depending on your particular rack ...

Страница 58: ...ay 2013 21 Connect required and optional cables See Connecting Cables on page 77 Related Information 600 mm Hardmount Kit 4 Post Rack on page 41 Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 ...

Страница 59: ...Time on page 91 Installing the 19 Inch Hardmount Kit 2 Post Rack Use these topics to install the server using an optional 19 inch hardmount rack kit into a 19 inch wide 2 post rack 19 Inch Hardmount Rack Kit 2 Post Rack on page 52 Step Description Links 1 Install optional components Optional Components on page 22 2 Review cautions Rack Cautions on page 23 3 Stabilize the rack Stabilize the Rack on...

Страница 60: ...mount Rack Kit on page 53 Related Information Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 19 Inch Hardmount Rack Kit 2 Post Rack TABLE 19 Inch 2 Post Hardmount Rack Kit Contents No Description 1 Rear plates 2 2 Screws 3 Side brackets 2 ...

Страница 61: ...andling Precautions on page 20 and ESD Precautions on page 21 3 Read the rack cautions and stabilize the rack See Rack Cautions on page 23 and Stabilize the Rack on page 24 4 Using four of the M5 x 7 SEM screws for each side bracket secure the side brackets to the sides of the server TABLE 19 Inch 2 Post Hardmount Rack Screws Quantity Description Where Used 10 M5 x 7 SEM screws 8 for side brackets...

Страница 62: ...ver X3 2 Installation Guide May 2013 5 Lift the server into the rack 6 Using two screws for each bracket secure the front of the server to the front of the rack The size of the screws varies depending on your rack ...

Страница 63: ...d to one of the three sets of eyelets on each side bracket depending on the thickness of the post a Using two of the M3 x 8 SEM screws for each rear plate loosely install the screws in one of the six positions on the rear plate The position varies depending on the thickness of the rail in the rack For example the following figure shows where you would install the screws for the optimum rack positi...

Страница 64: ...n Guide May 2013 b Slide the rear plate in so that the screws slide into position into one set of the eyelets The screw heads should be facing the rear of the server The other side of the rear plate should be in front of the rack post ...

Страница 65: ...t Rack 57 c Tighten the screws to secure the rear plate to the set of eyelets on the side bracket d Using two screws secure the other side of the rear plate to the back of the post The size of the screws varies depending on your rack ...

Страница 66: ...to secure the rear plate on the other post 8 Connect required and optional cables See Connecting Cables on page 77 Related Information 19 Inch Hardmount Rack Kit 2 Post Rack on page 52 Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 ...

Страница 67: ... to install the server into a 2 post rack using the optional 19 inch sliding rail kit 19 Inch Sliding Rail Kit 2 Post Rack on page 60 Install a Server 2 Post 19 Inch Sliding Rail Kit on page 61 Related Information Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 ...

Страница 68: ...tallation Guide May 2013 19 Inch Sliding Rail Kit 2 Post Rack TABLE 19 Inch Sliding Rail Kit Contents No Description 1 Slide assemblies 2 2 Inside glides 2 3 Screws 4 Cable management arm Not shown Threaded strips M6 4 10 32 4 ...

Страница 69: ... of the back rail 1 Gather the required tools See Tools Needed for Installation on page 22 2 Read the server cautions See Handling Precautions on page 20 and ESD Precautions on page 21 3 Read the rack cautions and stabilize the rack See Rack Cautions on page 23 and Stabilize the Rack on page 24 TABLE 19 Inch Sliding Rail Screws Quantity Description Where Used 10 M4 x 0 5 mm x 5 mm Phillips panhead...

Страница 70: ...he green button on each slide assembly and pull the right side and left side inner glides completely out of the slides 6 Using eight of the M4 x 0 5 x 5 mm Phillips panhead screws from the rackmount kit four for each side attach each glide to the side of the server chassis No Description 1 Glide 2 Button 3 Slide ...

Страница 71: ...front bracket to the desired position at the front of the rack and attach a front bracket to each of the front rack posts To secure each bracket use two of the M5 x 12 7 mm screws or two of the M6 x 13 mm screws Tighten the screws enough to secure the brackets but leave the brackets loose enough for adjustment later ...

Страница 72: ...0 32 holes use the 10 32 collar screws and 10 32 threaded strips 10 Align the glides attached to the server with the slide assemblies in the rack You might find that there is too much or too little room between the two slides mounted in the rack consequently the glides attached to the server might not align correctly with the slides in the rack If either situation occurs loosen the screws on the f...

Страница 73: ...Installing the Server in a 2 Post Rack 65 12 Fully tighten the screws on the front brackets 13 Fully tighten the screws on the rear brackets ...

Страница 74: ...Attach the CMA to the right rail note labels on the rails and the CMA on the right side There are labels on both the rails and the CMA The CMA side that has an arrow attaches to the right inner glide The other side of the CMA attaches to the outer member ...

Страница 75: ...r in a 2 Post Rack 67 15 Attach the CMA to the left rail There are labels on both the rails and the CMA The CMA side that has an arrow attaches to the left inner glide The other side of the CMA attaches to the outer member ...

Страница 76: ...age 22 Handling Precautions on page 20 Rack Cautions on page 23 Installing the 23 Inch Hardmount Kit 2 Post Rack Use these topics to install the server into a 2 post rack using the optional 23 inch hardmount kit 23 Inch Hardmount Kit 2 Post Rack on page 69 Install the Server 23 Inch Hardmount Kit on page 70 Related Information Tools Needed for Installation on page 22 Handling Precautions on page 2...

Страница 77: ...t Contents No Description 1 Side brackets 2 2 Screws 3 Rear plates 2 4 Rail guides 2 TABLE 23 Inch Rackmount Screws Quantity Description Where Used 10 M5 x 7 SEM screws 8 for side brackets 2 for rear plates 10 M5 x 12 7 mm screws 10 for rack if appropriate 10 M6 x 13 mm screws 10 for rack if appropriate ...

Страница 78: ...ed tools See Tools Needed for Installation on page 22 2 Read the server cautions See Handling Precautions on page 20 and ESD Precautions on page 21 3 Read the rack cautions and stabilize the rack See Rack Cautions on page 23 and Stabilize the Rack on page 24 4 Using eight of the M5 x 7 SEM screws four for each side bracket secure the side brackets to the sides of the server 9 M6 square clip nuts 9...

Страница 79: ...the Server in a 2 Post Rack 71 5 Lift the rail guides to the desired height in the rack and using two screws each secure both rail guides to the rack The size of the screws varies depending on your particular rack ...

Страница 80: ...72 Netra Server X3 2 Installation Guide May 2013 6 Lift the server into the rack and slide the server onto the rail guides ...

Страница 81: ...o further secure the server to the rack The rear plates attach to the rear of the post and to one of the three eyelets on each side bracket depending on the thickness of the post a Using one M5 x 7 SEM screw for each rear plate loosely install the screw in one of the three positions on the rear plate The position varies depending on the thickness of the rail in the rack For example the following f...

Страница 82: ...ion Guide May 2013 b Slide the rear plate in so that the screw slides into position into one of the eyelets The screw head should be facing the rear of the server The other side of the rear plate should be in front of the rack post ...

Страница 83: ...nstalling the Server in a 2 Post Rack 75 c Tighten the screw to secure the rear plate to the eyelet on the side bracket d Using two screws secure the other side of the rear plate to the back of the post ...

Страница 84: ...Repeat Step a through Step d to secure the rear plate on the other post 9 Connect required and optional cables See Connecting Cables on page 77 Related Information 23 Inch Hardmount Kit 2 Post Rack on page 69 Tools Needed for Installation on page 22 Handling Precautions on page 20 Rack Cautions on page 23 ...

Страница 85: ...and Site Specifications on page 9 Preparing for Installation on page 19 Installing the Server in a 4 Post Rack on page 27 Installing the Server in a 2 Post Rack on page 51 Powering On the Server the First Time on page 91 Step Description Links 1 Plan and configure server connections Connecting Data and Management Cables on page 78 2 Optional Review connector descriptions and pinouts Identifying Po...

Страница 86: ...nections except the Ethernet and power connections must be made using shielded cables and both ends of the shield must be grounded Caution All data cable connections are restricted to intra building interfaces and must be isolated from the exposed outside plant cabling Using primary protectors does not eliminate this restriction Ensure that these connections do not connect metallically to interfac...

Страница 87: ...connections to the SP USB keyboard USB mouse For pinout information see USB Ports on page 86 2 VGA Provides a video connection to the SP Note This port is for temporary use during installation or service procedures and has a maximum cable length limit of 6 meters VGA monitor and cable not to exceed 6 meters For pinout information see Video Port on page 86 ...

Страница 88: ...SP using the Oracle ILOM CLI and web interface By default this port is configured to use DHCP or an IPv6 router to automatically obtain an IP address Alternatively you can assign a static IP address to this port To use this port it must have its network settings configured Once configured you use the NET MGT port IP address to login to the SP using a browser or secure shell An Ethernet cable to co...

Страница 89: ...age 82 Identifying Ports on page 82 Rear Panel Components Installation on page 7 Cable the Ethernet Ports Once the server is running the OS these connections provide Ethernet access to the server See Gigabit Ethernet Ports on page 84 Note The Oracle ILOM sideband management feature enables you to access the SP using one of these Ethernet ports Refer to the Server Administration for instructions 1 ...

Страница 90: ...Ports on page 86 Video see Video Port on page 86 Alarms Alarm Port on page 88 Related Information Available Connections on page 78 Cable the SP on page 81 Cable the Ethernet Ports on page 81 Identifying Ports on page 82 Rear Panel Components Installation on page 7 Identifying Ports These topics provided connector descriptions and pinouts See Rear Panel Components Installation on page 7 for the loc...

Страница 91: ...ameters 8N1 eight data bits no parity one stop bit 9600 baud Disable hardware flow control CTS RTS Disable software flow control XON XOFF Caution Do not attach a modem to this port Related Information Available Connections on page 78 Rear Panel Components Installation on page 7 NET MGT Port on page 84 Gigabit Ethernet Ports on page 84 USB Ports on page 86 Video Port on page 86 Alarm Port on page 8...

Страница 92: ...This port does not support connections to Gigabit networks Related Information Available Connections on page 78 Rear Panel Components Installation on page 7 SER MGT Port on page 83 Gigabit Ethernet Ports on page 84 USB Ports on page 86 Video Port on page 86 Alarm Port on page 88 Gigabit Ethernet Ports The server has four RJ 45 10 Gigabit Ethernet 10GbE network connectors labeled NET 3 NET 2 NET 1 ...

Страница 93: ...tion on page 7 SER MGT Port on page 83 NET MGT Port on page 84 USB Ports on page 86 Video Port on page 86 Alarm Port on page 88 Connection Type IEEE Terminology Speed LED Color Transfer Rate Fast Ethernet 100BASE TX Off 100 Mbits sec Gigabit Ethernet 1000BASE T Amber 1000 Mbits sec 10 Gigabit Ethernet 10GBASE T Green 10000 Mbits sec Pin Signal Description Pin Signal Description 1 Transmit Receive ...

Страница 94: ...vices to each of the four USB controllers two ports in front two ports in rear for a total of 504 USB devices per server Related Information Available Connections on page 78 Rear Panel Components Installation on page 7 SER MGT Port on page 83 NET MGT Port on page 84 Gigabit Ethernet Ports on page 84 Video Port on page 86 Alarm Port on page 88 Video Port The server has one 15 pin VGA video port on ...

Страница 95: ...ation on page 7 SER MGT Port on page 83 NET MGT Port on page 84 Gigabit Ethernet Ports on page 84 USB Ports on page 86 Alarm Port on page 88 Pin Signal Description Pin Signal Description 1 Red Video 9 5V 2 Green Video 10 Sync Ground 3 Blue Video 11 Monitor ID Bit 0 Ground 4 Monitor ID Bit 2 Ground 12 VGA 12C Serial Data 5 Ground 13 Horizontal Sync 6 Red Ground 14 Vertical Sync 7 Green Ground 15 VG...

Страница 96: ...corresponding alarm LED on the front panel ALARM0 and the Critical LED ALARM1 and the Major LED ALARM2 and the Minor LED ALARM3 and the User LED Related Information Available Connections on page 78 Rear Panel Components Installation on page 7 SER MGT Port on page 83 NET MGT Port on page 84 Gigabit Ethernet Ports on page 84 Pin Signal Description Pin Signal Description 1 RESET0 9 ALARM1_NC 2 RESET0...

Страница 97: ...Connecting Cables 89 USB Ports on page 86 Video Port on page 86 ...

Страница 98: ...90 Netra Server X3 2 Installation Guide May 2013 ...

Страница 99: ... Server in a 2 Post Rack on page 51 Connecting Cables on page 77 Step 1 Review power requirements AC and DC Power Supply Specifications on page 11 Input Power Information on page 12 Overcurrent Protection Requirements on page 13 DC Power Source Power Connection and Grounding Requirements on page 14 2 Apply either AC or DC power to the server Connect AC Power Cords on page 92 Assembling DC Power Co...

Страница 100: ...le ILOM firmware Note If you do not connect a serial terminal or a terminal emulator you will not see the system messages 1 Ensure that you have a connection to the SP See Cable the SP on page 81 Note The server goes into Standby mode and the service processor initializes as soon as the AC power cord is connected to the power source By having a connection to the SP you can view and interact with t...

Страница 101: ...e Power On the Host for the First Time on page 103 Related Information Connect the Chassis Ground Wire on page 94 Power On the Host for the First Time on page 103 Assembling DC Power Cords and Applying DC Power No Description 1 Power supply 1 2 Power supply 0 Step Description Links 1 Connect the chassis to earth ground Connect the Chassis Ground Wire on page 94 2 Build the DC power cords Assemble ...

Страница 102: ...eptable to have both grounds connected This procedure is optional for servers with AC input power It is acceptable to ground the server through the supplies and chassis ground wire 1 Retrieve the grounding lug and two M5 nuts from the shipping kit 2 Insert the grounding wire into the receptacle of the grounding lug and use a crimping tool to crimp the receptacle around the wire 3 Go to the back of...

Страница 103: ... page 103 Assemble the DC Input Power Cord Assemble one DC input power cable for each DC power input to your server 1 Verify that you have met these conditions Install a DC power source that meets the server s input power specifications See AC and DC Power Supply Specifications on page 11 Secure DC power cables that meet the server s power cabling specifications See DC Power Source Power Connectio...

Страница 104: ...s are included in the shipping kit that came with your server 4 Locate the three wires coming from your DC power source that will be used for the connection to your server 48V or 60V negative terminal Chassis ground 48V or 60V Return positive terminal Note Depending on the DC power source the 48V or 60V negative terminal might be marked with a minus symbol The 48V or 60V Return positive terminal m...

Страница 105: ... of the DC input plug by taking one of these actions Insert the tip of the cage clamp operating lever into the rectangular hole directly above the hole in the DC input plug where you want to insert the first wire Press down on the cage clamp operating lever See the first figure Insert a small slotted screwdriver into the rectangular hole directly above the hole in the DC input plug where you want ...

Страница 106: ...ion Guide May 2013 7 Feed the exposed section of the appropriate wire into the round hole in the DC input plug No Description 1 DC input plug No Description 1 DC input plug No Description 1 Top of connector 2 From 48V or 60V return ...

Страница 107: ...formation Connect the Chassis Ground Wire on page 94 Install Strain Relief Housings on page 99 Connect DC Power Cords on page 102 Power On the Host for the First Time on page 103 Install Strain Relief Housings 1 Ensure that you have connected the chassis ground wire and assembled the DC input power cords See Connect the Chassis Ground Wire on page 94 and Assemble the DC Input Power Cord on page 95...

Страница 108: ...Installation Guide May 2013 3 Route the three wires coming from the DC power source through the opening at the bottom end of the strain relief housing 4 Insert a tie wrap into the bottom portion of the strain relief housing ...

Страница 109: ...ing tightening the tie wrap to secure the wires to the strain relief housing 6 Lower the top portion of the strain relief housing so that the three prongs on the top portion insert into the openings in the DC input plug Push the top and bottom portions of the strain relief housing together until they snap into place ...

Страница 110: ...minal emulator is not connected to the SER MGT port before power is applied Note Oracle ILOM will signal a fault if power is not applied to both supplies because that situation is a nonredundant condition 2 Ensure that the input cables are de energized with no DC power present Caution Do not proceed with these instructions until you are sure that there is no voltage present on the DC power cables ...

Страница 111: ...pt displays on the terminal device However the host is not initialized or powered on yet 8 Power on the server See Power On the Host for the First Time on page 103 Related Information Connect the Chassis Ground Wire on page 94 Assemble the DC Input Power Cord on page 95 Install Strain Relief Housings on page 99 Power On the Host for the First Time on page 103 Power On the Host for the First Time T...

Страница 112: ...the server boots the GRUB menu appears providing prompts to install the preinstalled OS From the GRUB menu you can choose whether you want to continue to direct the display to the serial port or whether you want to direct the display to a device connected to the video port Note By default the system displays the output to the serial port If you do not select an option on the GRUB menu after 10 sec...

Страница 113: ... install and configure a different OS on the server To install an OS on the Netra Server X3 2 formerly Sun Netra X4270 M3 Server from Oracle refer to Server OS Installation Related Information Connect AC Power Cords on page 92 Assembling DC Power Cords and Applying DC Power on page 93 ...

Страница 114: ...106 Netra Server X3 2 Installation Guide May 2013 ...

Страница 115: ...tandard format Netra products only ASR Automatic system recovery AWG American wire gauge B BAT basic assurance test BIOS Basic Input Output System blade Generic term for server modules and storage modules See server module and storage module blade server Server module See server module BMC Baseboard management controller BOB Memory buffer on board ...

Страница 116: ...e components in the modular system chassis See Modular system and Oracle ILOM CMM Oracle ILOM Oracle ILOM that runs on the CMM See Oracle ILOM D DHCP Dynamic Host Configuration Protocol disk module or disk blade Interchangeable terms for storage module See storage module DTE Data terminal equipment E ECC Error correcting code EIA Electronics Industries Alliance ESD Electrostatic discharge F FEM Fa...

Страница 117: ... hardware that runs the Oracle Solaris OS and other applications The term host is used to distinguish the primary computer from the SP See SP I ICMP Internet Control Message Protocol IDE Integrated Development Environment ID PROM Chip that contains system information for the server or server module IP Internet Protocol K KVM Keyboard video mouse Refers to using a switch to enable sharing of one ke...

Страница 118: ...odular system provides Oracle ILOM through its CMM MSGID Message identifier N name space Top level Oracle ILOM CMM target NEBS Network Equipment Building System Netra products only NEM Network express module NEMs provide 10 100 1000 Mbps Ethernet 10GbE Ethernet ports and SAS connectivity to storage modules NET MGT Network management port An Ethernet port on the server SP the server module SP and t...

Страница 119: ...rating system OS Operating system OSA Oracle System Assistant P PCI Peripheral component interconnect PCI EM PCIe ExpressModule Modular components that are based on the PCI Express industry standard form factor and offer I O features such as Gigabit Ethernet and Fibre Channel PDB power distribution board PMR Physical media request POST Power on self test PROM Programmable read only memory PSH Pred...

Страница 120: ...des the main compute resources CPU and memory in a modular system Server modules might also have onboard storage and connectors that hold REMs and FEMs SLES SUSE Linux Enterprise Server SMART Self Monitoring Analysis and Reporting Technology SNMP Simple network management protocol SP Service processor In the server or server module the SP is a card with its own OS The SP processes Oracle ILOM comm...

Страница 121: ...iversal connector port UEFI Unified Extensible Firmware Interface UI User interface UL Underwriters Laboratory Inc U S NEC United States National Electrical Code UTC Coordinated Universal Time UUID Universal unique identifier V VM Virtual machine W WDS Windows Deployment Services WIM Windows Imaging Format WWN World wide name A unique number that identifies a SAS target ...

Страница 122: ...114 Netra Server X3 2 Installation Guide May 2013 ...

Страница 123: ...stic noise emissions 16 airflow clearance 16 alarm connectors 3 port 7 88 ambient temperature 15 amperage 13 antitilt bar 20 applying power AC servers 92 DC servers 93 assembling DC power cords 93 95 available connections 78 B branch circuit 14 C cables Category 6 81 connecting 77 cabling Ethernet ports 81 SP 81 cage clamp 95 Category 6 cables 81 cautions DC power 14 rack 23 chassis ground posts 7...

Страница 124: ...6 environmental requirements 15 equipment loading 23 ESD mat 22 precautions 21 Ethernet ports 3 7 78 cabling 81 F fans 3 features server 3 frequency specifications 11 front panel components 5 G ground posts 7 14 94 ground wire connecting 94 grounding 23 requirements 14 strap 22 H handling precautions 20 height 10 host powering on the first time 103 humidity specifications 15 I identifying ports 82...

Страница 125: ...r grounding 7 Power button location 5 power connection DC 14 power source DC 14 power supplies 3 7 power supply LED 5 specifications 11 power input 12 powering on host 103 server 91 precautions installation ESD 21 handling 20 preparing for installation server 19 R rack cautions 23 stabilization 24 rackmounting 2 post 19 inch hardmount 52 19 inch slide mount 60 23 inch hardmount 70 4 post 19 inch s...

Страница 126: ...ature 15 voltage 11 stabilizing the rack 24 Start HOST console 103 start System 103 status indicators front panel 5 rear panel 7 storage supported 3 strain relief housing 95 installing 99 stripping DC wires 95 support viii supported alarm connectors 3 cooling fans 3 Ethernet ports 3 optical media 3 PCIe slots 3 power supplies 3 SP 3 storage 3 USB 2 0 slots 3 surge protector 12 switches 3 System OK...

Отзывы: