Alarm
Alarm ID
Alarm
Severity
Cause(s)
Log Message Graphic
Display
Window
Message
PLD
VOLTAGE
ALARM 2P5V
(2.5 Volt Rail)
65544
MINOR
EMERGENCY
A PLD
exceeds a
predetermined
threshold
Voltage 2.5V
CPU has
minor alarm
Voltage 2.5V
CPU has
emergency
alarm, the
system should
shut down
X HW
ALARMS:
(where X is
the number of
hardware
alarms
PLD
VOLTAGE
ALARM 3P3V
(3.3 Volt Rail)
65545
MINOR
EMERGENCY
A PLD
exceeds a
predetermined
threshold
Voltage 3.3V
has minor
alarm
Voltage 3.3V
has
emergency
alarm, the
system should
shut down
X HW
ALARMS:
(where X is
the number of
hardware
alarms
PLD
VOLTAGE
ALARM 5V
(5 Volt Rail)
65546
MINOR
EMERGENCY
A PLD
exceeds a
predetermined
threshold
Voltage 5V
has minor
alarm
Voltage 5V
has
emergency
alarm, the
system should
shut down
X HW
ALARMS:
(where X is
the number of
hardware
alarms
PLD
VOLTAGE
ALARM CPU
(Host Voltage)
65547
MINOR
EMERGENCY
A PLD
exceeds a
predetermined
threshold
Voltage CPU
has minor
alarm
Voltage CPU
has
emergency
alarm, the
system should
shut down
X HW
ALARMS:
(where X is
the number of
hardware
alarms
NIU Alarms
The following table lists the NIU alarms. PHY0 and PHY1 are both located on the
same NIU. PHY0 encompasses S0P0 and S0P1, while PHY1 encompasses S1P0 and
S1P1. Therefore, both insertion and both removal alarms will be activated at the same
time when the NIU is inserted or removed from the Acme Packet 4600.
Alarm
Alarm ID
Alarm Severity
Cause(s)
Log Message
PHY0 Removed
65550
MAJOR
NIU S0Px was
removed
Physical interface
card 0 has been
removed
PHY0 Inserted
65552
MAJOR
NIU S0Px was
inserted
None
Chapter 6
Alarms
6-36