Chassis Removal
This section explains how to remove the Acme Packet 4600 from an equipment rack.
To prevent injury, Acme Packet recommends that any time a Acme Packet 4600 is
installed or removed from an equipment rack, two people complete the procedure.
Note:
You must first review the safety precautions for the Acme Packet 4600 prior
to removing from an equipment rack.
Note:
Always disconnect the Acme Packet 4600 power supplies from the power
source when removing a chassis from an equipment rack
Removing the Acme Packet 4600 System from an Equipment Rack rack
To remove the Acme Packet 4600 from an equipment:
1.
Set the System Power switch to the Stby position to cut off power to the Acme
Packet 4600.
2.
Remove the two power cords from the power supplies in the rear of the system.
(There are no on/off switches on these power supplies).
3.
Remove all power cables from the Acme Packet 4600.
4.
Remove and label all attached network cables, alarm cable, and console cables
from their respective ports on the chassis.
5.
Loosen the thumbscrews that secure the Acme Packet 4600 to the
equipment rack slide rails. This may require using a #2 Phillips screwdriver.
Note:
Beginning in this step, one person should support the Acme Packet 4600
from below while the other person removes the system chassis from the
equipment rack.
6.
Pull the Acme Packet 4600 forward and out of the equipment rack.
Chapter 6
Chassis Removal
6-7