Using This Guide
Read and understand all notes of warning and caution included in the Acme Packet
4600 System documentation. These warnings and cautions are designed to keep you
safe and protect the Acme Packet 4600 System from damage.
Precautions
To protect yourself from harm and the Acme Packet 4600 System from damage, follow
these electrical safety precautions:
Precautions
•
Note the locations of the System Power switch on the Acme Packet 4600 and the
location of the emergency power-off switch for the room where the Acme Packet
4600 is located.
•
If an electrical accident occurs, remove power from the system immediately by
unplugging the chassis.
•
Always disconnect the power from the system when removing a Acme Packet
4600 System from its rack.
•
When disconnecting power:
–
Turn the System Power switch to the Stby position.
–
Disconnect the circuit breaker at the rack.
–
Unplug or unscrew the power cords from the power supplies.
•
Use grounded AC power cords that are plugged into grounded electrical outlets.
•
Never use extension cords to power a Acme Packet 4600.
•
Ensure that the installation facilities have proper grounding systems and include a
grounded rack structure or local grounding bus bar.
•
When installing the Acme Packet 4600 System in an equipment rack, always
make the ground connection first and disconnect it last when removing it.
•
Use shielded Category 5e or 6, RJ45 cables for all 10/100/1000 Ethernet
connections to protect the Acme Packet 4600 System from potential damage.
•
To avoid making a complete circuit (which causes electrical shock), use only one
hand when working with powered-on electrical equipment.
•
Use caution when using electrically conductive tools around the Acme Packet
4600 System.
•
Remove jewelry before working on the Acme Packet 4600 System.
Battery Warning
There is a risk of explosion if the battery is replaced by an incorrect type. Dispose of
used batteries according to the instructions.