7.
When mounted in slide rails, the chassis will stop when the locking clip
pin on the chassis slide rail engages with the equipment rack slide rail.
8.
Push on the locking clip pin and locking clip
latch to unlock the slide rails from each other.
9.
Remove the chassis completely from the slide rails.
10.
Lift the Acme Packet 4600 out of the equipment rack, and move it to an ESD-safe
location.
Power Supply Removal and Replacement
This section explains how to remove and replace the power supplies in the Acme
Packet 4600 chassis.
Note:
After physically unplugging a power supply, disconnect it from the power
source before you remove or install it in the chassis.
The power supply is a user-replaceable component. If an Acme Packet 4600 power
supply malfunctions, you should remove the malfunctioning power supply and replace
it.
Note:
Power supplies can be removed from the chassis while it is still installed in
the rack and while the second power supply is providing system power; this
is called a warm swap.
Note:
When removing and replacing a power supply, remember to first ground
yourself using appropriate ESD grounding equipment such as a wrist strap.
Chapter 6
Power Supply Removal and Replacement
6-8