Measurement Characteristics
l
Electronics based on a Microprocessor
l
Support telediagnostics and telemaintenance
l
Possibility to configure remotely the functional parameters
l
When maintenance is necessary, the internal parts of the probe can be removed and it will not be
necessary to remove fuel from the tank. This is good for LPG applications where tanks are pressurized.
l
Stainless steel case, IP68.
l
Probe shaft Stainless Steel AISI 304 / 316
l
Measurement range: from 200 mm. to 12.500 mm.
l
Maximum mechanical length: 13.000 mm.
l
Data transmitted:
n
Product level in 0.01 mm
n
Water level in 0.01 mm
n
Medium temperature detected through digital temperature sensor placed along the probe shaft
(standard 1, max 5)
l
Measurement accuracy: Better than +/- 0.5 mm.
l
Measurement resolution: +/- 0.01 mm.
l
Temperature accuracy: +/- 0,2°C
l
Approvals :
n
OIML-R85 for fixed applications
n
OIML-R80 per mobile applications (pending)
Installation
NOTICE:
Install this electronic device carefully. Make sure the stainless steel tube does
not bend when installed in a tank man-hole. This could cause damage to the electronic
components inside.
Probe placement: Please refer to
for instructions on probe installation
location and distances from fill tubes and pumps.
Before you install the probe, be sure the floats are positioned correctly. Make sure the plastic probe shaft end
cap is correctly installed on the bottom of the probe shaft so that the floats can correctly identify water and fuel
levels.
Make sure that when a riser is used, that the probe is installed high enough so it cannot get flooded. Put the
probe through the 2 inch opening and carefully lower it until it touches the bottom of the tank.
Doc. No.: M2010-EU Rev.: 13
Page 116 of 149
Содержание M2010-EU
Страница 6: ...Warranty 147 Doc No M2010 EU Rev 13 Page 6 of 149...
Страница 20: ...Main Board Connections Jumpers and LEDs Doc No M2010 EU Rev 13 Page 20 of 149...
Страница 21: ...Conduit Installation Doc No M2010 EU Rev 13 Page 21 of 149...
Страница 22: ...Field Wiring Diagram Doc No M2010 EU Rev 13 Page 22 of 149...
Страница 32: ...Doc No M2010 EU Rev 13 Page 32 of 149...
Страница 38: ...924B Probe Installation DMP Probe Installation Doc No M2010 EU Rev 13 Page 38 of 149...
Страница 41: ...Doc No M2010 EU Rev 13 Page 41 of 149...
Страница 86: ...Typical Installation Drawings 30 0230 S Doc No M2010 EU Rev 13 Page 86 of 149...
Страница 110: ...Appendix C Declaration of Conformity Doc No M2010 EU Rev 13 Page 110 of 149...
Страница 111: ...Doc No M2010 EU Rev 13 Page 111 of 149...
Страница 112: ...Doc No M2010 EU Rev 13 Page 112 of 149...
Страница 113: ...Doc No M2010 EU Rev 13 Page 113 of 149...
Страница 142: ...Doc No M2010 EU Rev 13 Page 142 of 149...
Страница 146: ...Doc No M2010 EU Rev 13 Page 146 of 149...
Страница 149: ......