5.6 Nano Mixed Multi-drop Installation
The Nano's internal I.S. barrier can hold a maximum of 12 probes and 24 sensors. The console uses a point
system to calculate the mix of probes and sensors that can be installed on each of the four (4) barrier
positions.
NOTE:
The OPW-FMS model 924B probe and the DMP probe can be on the same internal
Nano I.S. barrier position for multi-drop installations. The two probes are equal to the same
point values to calculate the mix of probes and sensors on a barrier position.
One (1) probe (924B and/or DMP) is equal to three (3) points and one (1) sensor is equal to one (1) point.
One barrier position can hold a total of 12 points (4 Tank-Probes, or 12 Smart-Sensors or a mix of probes
and sensors).
Some examples of possible Mixed Multi-drop barrier channel installations are shown below. Other
combinations are possible if the total number of points is not more than 12 on one barrier.
Doc. No.: M2010-EU Rev.: 13
Page 43 of 149
Содержание M2010-EU
Страница 6: ...Warranty 147 Doc No M2010 EU Rev 13 Page 6 of 149...
Страница 20: ...Main Board Connections Jumpers and LEDs Doc No M2010 EU Rev 13 Page 20 of 149...
Страница 21: ...Conduit Installation Doc No M2010 EU Rev 13 Page 21 of 149...
Страница 22: ...Field Wiring Diagram Doc No M2010 EU Rev 13 Page 22 of 149...
Страница 32: ...Doc No M2010 EU Rev 13 Page 32 of 149...
Страница 38: ...924B Probe Installation DMP Probe Installation Doc No M2010 EU Rev 13 Page 38 of 149...
Страница 41: ...Doc No M2010 EU Rev 13 Page 41 of 149...
Страница 86: ...Typical Installation Drawings 30 0230 S Doc No M2010 EU Rev 13 Page 86 of 149...
Страница 110: ...Appendix C Declaration of Conformity Doc No M2010 EU Rev 13 Page 110 of 149...
Страница 111: ...Doc No M2010 EU Rev 13 Page 111 of 149...
Страница 112: ...Doc No M2010 EU Rev 13 Page 112 of 149...
Страница 113: ...Doc No M2010 EU Rev 13 Page 113 of 149...
Страница 142: ...Doc No M2010 EU Rev 13 Page 142 of 149...
Страница 146: ...Doc No M2010 EU Rev 13 Page 146 of 149...
Страница 149: ......