V 1.0 - eng
85
COE LS-X Line Scan Camera | USER MANUAL
Parameter
Read/Write
Description
Device Link Speed
(Mbps)
Read only
It is the link speed.
Device Link Connection
Count
Read only
It is the number of link connections.
Device Link Heartbeat
Mode
Read and
write
It enables heartbeat mode or not.
Device Stream Channel
Count
Read only
It is the number of stream channels.
Device Stream Channel
Selector
Read and
write
It selects the stream channel.
Device Stream Channel
Type
Read only
It is the stream channel type.
Device Stream Channel
Link
Read only
It is the device link associated with the stream
channel.
Device Stream Channel
Endianness
Read only
It is the image data endianness.
Device Stream Channel
Packet Size (B)
Read and
write
It is the data packet size.
Device Event Channel
Count
Read only
It is the channel quantity that the device supports.
Device Character Set
Read only
It is the character set used in register.
Device Reset
Read and
write
Click Execute to reset the device.
Device Temperature
Selector
Read and
write
It selects device component to view temperature.
Sensor supported only.
Device Temperature
Read only
It is the selected device component temperature.
Find Me
Read and
write
Click Execute to let red indicator flash, and find
device.
Device Max Throughput
(Kbps)
Read only
It is the maximum flow of device operation.
Device PJ Number
Read only
It is the device serial number.
HB Abnormal
Monitor
Read only
It is used to monitor image stream condition.
If the size of compressed image is larger
than that of raw image under HB function,
this parameter will increase. When this
parameter increases rapidly, it is