When selecting bi-directional configurable line as the hardware trigger source, you need to make
sure that its line mode is input. Go to
Digital IO Control
, select specific line as
Line Selector
, and
Input
as
Line Mode
.
Here we take Line 2 as an example to introduce how to set bi-directional configurable line as the
hardware trigger source. Refer to your camera for the actual condition.
Figure 1-14
Set Line 2 as Input Signal
You can also set the signal type for the selected bi-directional configurable line. Go to
Digital IO Control
, and set
Line Format
according to the desired value.
⚫
SingleEnded
: It can receive single-ended input signal.
⚫
Differential
: It can receive TTL & LVTTL standard input signal.
⚫
When selecting
Differential
as
Line Format
, the camera supports 5/12/24 VDC differential
signal input.
You need to select line format according to the external device connected. Otherwise, I/O may be
damaged.
7.5.3 Set Shaft Encoder Control
If the camera enables the line trigger, you can select
Encoder Module Out
as trigger source. At
this time, the camera will receive signal A and signal B with phase difference. After internal
computing, the output signal can be used as camera trigger signal. The illustration of shaft encoder
module is shown below.
Phase A
Phase B
Line Inp ut 1
Line Input 2
Line input 1 is
selected as the
input signal for
phase A
Line input 2 is
selected as th e
input signal for
phase B
Phase A Input
Phase B Input
Shaft Encod er
Software
Module
Line Trigger
Module
Output
The final output
of module is line
trigger s ignal