![opto engineering COE LS-X Series Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/opto-engineering/coe-ls-x-series/coe-ls-x-series_user-manual_1643934052.webp)
V 1.0 - eng
52
COE LS-X Line Scan Camera | USER MANUAL
Figure 1-54
12 V and 24 V Differential Signal Sources Output Differential Signal
With different voltages of differential signal sources, the respective resistance values in wiring are
also different, as shown below.
Table 1-19
Relation between Voltage and Resistance
VCC
R1
R2
12 V
6.2 K
4.7 K
24 V
18 K
4.7 K
⚫
Single-Ended Signal
The single-ended signals that the camera receives can be from the differential signal source or the
single-ended signal source.
The VCC of the differential signal source is 5 V, 12 V or 24 V.
OUT A
Differential Input Positive
Differential
Signal
Source
Camera Power
Signal Source Power
PWR
VCC
Camera Power Ground
Camera GND Signal Source GND
Signal Ground
Hang
Differential Input Negative
Signal Source Power Ground
Figure 1-55
Differential Signal Source Outputs Single-Ended Signal
When the PNP single-
ended signal source provides signal, and the camera’s differential input is
used as single-ended input. The VCC of PNP single-ended signal source is 5 V, 12 V or 24V.
Differential Input Positive
PNP Single-
Ended
Signal
Source
Camera Power
Signal Source Power
PWR
VCC
Camera Power Ground
Camera GND
Differential Input Negative
Signal Source GND
Signal Ground
Hang
Signal Line
Signal Source Power Ground
Figure 1-56
PNP Single-Ended Signal Source Connects Differential Input
When the PNP single-ended signal source provides bi-directional I/O to the camera, the wiring is
shown below. The VCC of PNP single-ended signal source is 12 V or 24 V.