The software trigger and action command trigger are valid for the frame trigger only, and the shaft
encoder control is valid for the line trigger only.
Table 1-9
External Trigger Mode Principle and Parameter
Trigger
Source
Parameter
Parameter
Value
Description
Software
trigger
Acquisition Control >
Trigger Source
Software
The software sends trigger signal to the
camera to acquire images.
Hardware
trigger
Acquisition Control >
Trigger Source
Specific Line
External device connects via camera I/O
interface. External device sends trigger signal
to camera to acquire images.
Shaft encoder
control
Acquisition Control >
Trigger Source
Encoder
Module Out
This trigger source uses shaft encoder module
to receive signal A and signal B with phase
difference. After internal computing of the
module, the output signal can be used as
camera’s trigger signal.
Frequency
converter
control
Acquisition Control >
Trigger Source
Frequency
Converter
This trigger source allows different frequency
between trigger camera signal and required
input signal.
Action
command
trigger
Acquisition Control >
Trigger Source
Action 1
The action command sends trigger signal to
the camera to acquire images. You can select
this trigger source only when the frame trigger
mode is set.
Free trigger
Acquisition Control >
Trigger Source
Anyway
Use trigger sources mentioned above to send
trigger signal to the camera to acquire images.
⚫
These trigger sources are valid only the frame trigger mode, line trigger mode or line+frame
trigger mode is enabled.
⚫
In line+frame trigger mode, if the trigger source selected and trigger parameters configured for
the frame trigger and the line trigger are the same, then the first signal of the trigger source is
used as the frame trigger signal to let the camera acquire images. The subsequent signals used
as the line trigger signal to acquire images until the completion of one frame image.
7.5.1 Set Software Trigger
The camera supports software trigger. When the software trigger is selected, the client software
sends commands to acquire and transmit images.
Steps: