Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
LINE*P
OUT A
LINE*N
OUT Ã
Power Ground of Trigger Device
Figure 1-64
Differential Output Wiring
When I/O signals are used as single-ended output, the wirings are different according to the voltages
of the triggered device.
⚫
If the triggered device needs a LVTTL of 3.3 V and below, the wiring is shown below.
Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
LINE*N
LINE*P
Power Ground of Trigger Device
Hang
Signal Line
Figure 1-65
Single-Ended Output Wiring without Pull-Up Resistor
⚫
If the triggered device needs a LVTTL of 5 V and above, you should add a pull-up resistor
between 1 K
Ω and 10 KΩ.