3. Click
Execute
in
Activate Shading
, and enable
PRNUC User Enable
.
4. (Optional) Enable
PRNUC Smooth Enable
to reduce the dust impact during calibration
process.
Figure 1-112
Set Shading Correction (III)
⚫
ROI PRNUC Correction
If you want to execute PRNUC correction for specific areas, set
PRNUC Width
and
PRNUC Offset
X
according to actual demands, and enable
PRNUC ROI Enable
.
Figure 1-113
ROI PRNUC Correction
10.22 Set Space Correction
The space correction function may differ by camera models.
The space correction (SC) includes line rate deviation correction and parallax deviation correction, and they
are used to reduce image details deviation caused by line rate deviation or pixel deviation.