KRM-X® Duct Smoke Detector

6

 | 

10

  |  Fire Protection  |  Data sheet No. 41350  |  Version 01-2019 

MIN 3xd

h

MIN 5xd

h

MIN 3xd

h

MIN 5xd

h

MIN 3xd

h

MIN 5xd

h

MIN 3xd

h

MIN 5xd

h

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

KRM

MIN 5xd

h

MIN 3xd

h

MIN 5xd

h

MIN 5xd

h

MIN 3xd

h

MIN 3xd

h

MIN 5xd

h

MIN 5xd

h

MIN 3xd

h

Exhaust air

Supply air

Ventilator

Airflap

Muffler

Battery

Air duct device

Air duct narrowing/

air duct enlargement

 

Air duct forking

Change of 

air duct direction

 

dh=

2xHxB

H+B

H

B

Rectangular duct

dh=D

øD

Round duct

Hydraulic diameter d

h

Example of positioning (recommendation)

air collecting tube, may not be installed along the longitudinal 
edges of ventilation ducts (corner area). The KRM-X must be 
installed such that the air collecting tube is constantly located in 
the air stream. In horizontal ventilation ducts the KRM-X, includ-
ing the air collecting tube, should be installed in the upper third 
of the ventilation duct or at the top of the ventilation duct, if this 
is structurally possible.

If the positioning recommendations cannot be followed for  
structural reasons, the KRM-X should be mounted such that  
reliable smoke detection and airflow are nonetheless ensured. 
The blue airflow LED serves as an airflow indicator  
(the LED is off with sufficient flow).

Observe these instructions. All work (such as installation, electri-
cal connection, startup, operation, and maintenance) must only 
be performed by sufficiently qualified tradesmen. The respec-
tively applicable local rules and regulations (e.g. national building 
codes, electrical/VDE regulations, etc.) must be observed. Install-

ers and operating entities are required to sufficiently familiarize 
themselves before startup. Read the product description before 
operating the equipment. Verify that the product can be used 
for the relevant application without restrictions. We are not liable 
for printing errors and changes after printing. Appropriate use 
implies compliance with operating and installation instructions. 
We are not liable for losses due to inappropriate use. Unautho-
rized manipulations or modifications of the device render the 
operating permit, the product warranty and warranty claims null 
and void.

Содержание KRM-X

Страница 1: ...S485 MOD BAC only Accessories Mounting bracket KS X for insulated circular ducts KS X for insulated circular ducts in combination with WDG X Housing WDG X protective insulating housing with alarm disp...

Страница 2: ...nected Note The floating switching contacts terminals 11 17 should be assigned as uniformly as possible to an installation category according to EN 60730 1 These switching contacts are to be used for...

Страница 3: ...ng segment display 00 99 Contamination in Flashes starting at 70 contamination relay drops out at 99 the alarm LED alarm lights up Failure E g smoke detector missing communication with smoke detector...

Страница 4: ...when airflow is too low and air relay only present on DIBt versions drops out Check smoke detector position in the duct check sampling tube TurboTube for contamination and clean if necessary Programm...

Страница 5: ...unting bracket this makes it possible to mon itor ducts up to 100 mm There is no maximum width height or diameter for air ventilation ducts monitored with the 600 mm long standard air collecting tube...

Страница 6: ...structurally possible If the positioning recommendations cannot be followed for structural reasons the KRM X should be mounted such that reliable smoke detection and airflow are nonetheless ensured T...

Страница 7: ...lel to the flow direction Four self tapping screws not included in delivery serve for attaching the adapter plate to the sheet metal duct 4 Installation on the duct Rectangular air duct see picture on...

Страница 8: ...The green LED 12 lights up Press the alarm reset button 9 to perform a simple initial functional test All LEDs must light up and all relays drop out The units con nected to the relays are activated T...

Страница 9: ...ive to smoke while work is in progress If a brief shutdown cannot be cannot be tolerated for operational reasons measures must be taken to prevent a shutdown If necessary a bridge can be placed over t...

Страница 10: ...eturn to its normal function and does it unlock again from the smoke alarm state and return to its normal function when the alarm has been reset Does the detector return to the alarm state and lock up...

Отзывы: