16
Remote Switch and Meters
Onan Remote Control Panel Kits:
Remote control
panels with a control switch or a control switch with
DC voltmeter or hour meter are available as kits.
Follow the installation instructions in the kit.
These
panels are not ignition protected and must therefore
be installed in spaces isolated from gasoline fuel
sources.
Non-Onan Remote Control Panels:
Use Figure 6
as a guide for wiring a remote switch and meters to
mate with the genset remote connector. Start-Stop
switches must be momentary contact in both posi-
tions.
The panel must be installed in spaces iso-
lated from gasoline fuel sources unless all of its
components are ignition protected devices.
Remote Control Wiring Harnesses
Onan Harnesses:
Eight-conductor plug-in wiring
harnesses of various length are available for con-
necting
e-Series Digital Displays
and/or a remote
switch and meters.
Non-Onan Harnesses:
Use 16 AWG wiring. For
harnesses 45 to 150 feet (14 to 46 meters) long,
use 14 AWG wiring at connector pins 2, 3 and 4.
Harnesses for
e-Series Digital Displays
must have
eight (8) conductors.
Harnesses for remote switches and meters only
must have at least six (6) conductors (connector
pins 7 and 8 are not used). See Figure 6.
Note 1: All feed-through holes in decks and bulk-
heads for wiring must be sealed to prevent exhaust
gases and flammable vapors from entering the rest
of the boat. Wiring conduit must be sealed inside as
well as outside.
Note 2: Do not route remote control wiring near AC
wiring. AC can induce false signals that can cause
erratic operation of the genset.
Warning Labels
Each Onan kit for an
e-Series Digital Display
or re-
mote control panel includes the following label:
WARNING
Gasoline vapors can explode. Be-
fore starting the genset, operate the exhaust
blower for 4 minutes and check the genset
compartment and bilge for gasoline vapors.
This label or equivalent must be affixed next to each
e-Series Digital Display
or genset start switch and
be visible when starting the genset at that station.
STATUS LAMP
RUN LAMP
1
2
3
4
5
6
7
8
A
A
A−A
SEALED 8-PIN DEUTSCH
CONNECTOR
(MATE TO GENSET CONNECTOR)
REMOTE CONTROL PANEL
FIGURE 6. CONNECTIONS BETWEEN REMOTE PANEL AND ITS 8-PIN CONNECTOR
Redistribution or publication of this document,
by any means, is strictly prohibited.