1
1
LOAD WATERLINE
GENSET
MUFFLER
WATER-EXHAUST MIXER LEVEL
SEE OUTLINE DRAWING (PAGE 23)
WATER
SEPARATOR
18 INCH
(457 MM)
MIN.
MUST BE
ABOVE WA-
TERLINE
Notes:
1. All exhaust hose and pipe must slope, without sagging, at least 1/2 inch per foot (42 mm/meter).
2. The operator will not be able to look for water discharge from the hull to tell whether engine/exhaust cooling water is flowing.
However, the genset will shutdown if water stops flowing (Code No. 7). See
Troubleshooting
in the Operator’s Manual.
12 INCH
(305 MM)
MIN.
SIPHON BREAK
NOT
REQUIRED WHEN WATER-EXHAUST
MIXER IS
AT LEAST 6 INCHES (152 MM) ABOVE
LOAD WATER LINE
SEA
COCK
6 INCH
(152 MM)
MAX.
54 INCH
(1.4 METER)
MAX.
FIGURE 2. TYPICAL INSTALLATION ABOVE LOAD WATERLINE—WITH MUFFLER AND WATER SEPARATOR