13
GENSET
MUFFLER
SIPHON
BREAK
VALVE
WATER-EXHAUST MIXER LEVEL
SEE OUTLINE DRAWING (PAGE 23)
12 INCH
(305 MM)
MIN.
12 INCH
(305 MM)
MIN.
SEA
COCK
WATER
SEPARATOR
LOAD WATERLINE
54 INCH
(1.4 METER)
MAX.
18 INCH
(457 MM)
MIN.
MUST BE
ABOVE WA-
TERLINE
SIPHON BREAK REQUIRED WHEN WATER-EXHAUST MIXER IS
BELOW OR LESS THAN 6 INCHES (152 MM) ABOVE
LOAD WATER LINE
Notes:
1. All exhaust hose and pipe must slope, without sagging, at least 1/2 inch per foot (42 mm/meter).
2. The operator will not be able to look for water discharge from the hull to tell whether engine/exhaust cooling water is flowing.
However, the genset will shutdown if water stops flowing (Code No. 7). See
Troubleshooting
in the Operator’s Manual.
6 INCH
(152 MM)
MAX.
FIGURE 4. TYPICAL INSTALLATION BELOW LOAD WATERLINE—WITH A SIPHON BREAK, MUFFLER AND WATER SEPARATOR