I/O Timing Charts
ZX-GT User’s Manual
96
Explanation of Operation
(1)
Continuous measurement is started the moment that the mode changes to the RUN
mode.
(2)
When measurement ends and the measurement processing time elapses, the
measured data is applied and output.
(3)
Analog output is started after the measured data is applied and the analog output
response time (T3) elapses.
(4)
Output is executed for the time specified as the binary output cycle after the IFU
binary output response time (T4) elapses and the measured data is applied.
(5)
The GATE signal turns ON for the predetermined time and measured data is
captured on the external device after measured data is applied and the IFU binary
output response time (T4) elapses.
Measurement cycle: High-speed mode (FAST)
T1:
Measurement cycle
The measurement cycle is 0.5 ms.
Note, however, that the response time is 1 ms in the IC lead
pitch and IC lead width judgment modes.
T2:
Measurement processing time
This is the time required until the measured data is applied.
(max. 1 ms)
Note, however, that the response time is 1.5 ms in the IC lead
pitch and IC lead width judgment modes.
T3:
Analog output response time
This is the time until the Controller starts analog output after
completion of measurement. (100 µs)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Measurement timing 1
Measurement timing 2
Measurement timing 3
Controller judgment output
(output timer setting: OFF)
Controller
analog output
IFU binary output
IFU GATE output
T1
T3
T4
T5
T2
T1
T2
T1
T2
T6
(1)
(2)
(3)
(4)
(5)
T3
T3
T4
IFU: Stands for "Interface Unit".
zx_gt.book Page 96 Wednesday, May 30, 2007 3:29 PM
Содержание ZX-GT -
Страница 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Страница 12: ...ZX GT User s Manual 10 MEMO...
Страница 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Страница 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Страница 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Страница 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Страница 74: ...Setting Output Conditions ZX GT User s Manual 72 5 Check that setting of correction values is completed SUB...
Страница 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Страница 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Страница 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...