Set/Acquire IC Lead Pitch/IC Lead Width Standard Values < REF command >
This command is active only when the measurement mode is the IC lead pitch or IC lead
width judgment mode.
Setting standard values
Sets the IC lead pitch/IC lead width standard values.
< Command format >
< Response format >
< Explanation of parameters >
Standard values
Specifies the IC lead pitch/IC lead width standard values.
• IC lead pitch judgment mode (600 to 28000)
• IC lead width judgment mode (300 to 28000)
R E F
CR
Standard values (max. 6 digits)
O K
E R
CR
CR
When processing ends successfully
When processing fails