Error Messages and Corrective Actions
ZX-GT User’s Manual
140
Error Messages and Corrective Actions
The following shows error messages that are displayed on the main display and their
corrective actions.
Setup Errors
Measurement Errors
Error message
Probable cause and possible countermeasure
Reference
ERRLH
The setting is "LOW threshold > HIGH threshold -
hysteresis".
• Enter the LOW threshold so that "LOW threshold <
HIGH threshold - hysteresis".
p.45
ERRHL
The setting is "HIGH threshold < LOW thr
hysteresis".
• Enter the HIGH threshold so that "HIGH threshold >
LOW threshold - hysteresis".
p.45
ERROV
The set numeric value is too large.
• Enter an appropriate numeric value.
-
The setting is "hysteresis > HIGH threshold - LOW
threshold".
• Enter the hysteresis so that "hysteresis < HIGH
threshold - LOW threshold ".
p.67
ERRUD
The set numeric value is too small.
• Enter an appropriate numeric value.
-
Error message Probable cause and possible countermeasure
Reference
E-CHL
There are two Sensors but only one Controller connected.
• If two or more Controllers are connected to each other, turn OFF the power supply
and check that the Controllers and Calculating Units are connected correctly.
• If only one Controller is being used, connect two or more Controllers
temporarily and turn OFF two-Sensor operation, or initialize the settings data.
p.37
p.39
p.59
E-DAT
Two-Sensor operation communications data error
• Change the mode for the CH1 Controller to RUN.
• Turn OFF the power supply and check that the Controller and Calculating
Units are connected correctly. Replace the Controller or the Calculating Unit
if the above countermeasures do not solve the problem.
• When the SmartMonitor GT is in use, the two-Sensor operation error
occurs while the CH1 graph is displayed or during logging.
p.22
p.37
E-HED
The Sensor is disconnected.
• Turn OFF the power supply, check the connection for the Sensor, and
then turn ON the power supply again. Replace the Sensor if the above
countermeasure does not solve the problem.
p.28
zx_gt.book Page 140 Wednesday, May 30, 2007 3:29 PM
Содержание ZX-GT -
Страница 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Страница 12: ...ZX GT User s Manual 10 MEMO...
Страница 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Страница 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Страница 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Страница 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Страница 74: ...Setting Output Conditions ZX GT User s Manual 72 5 Check that setting of correction values is completed SUB...
Страница 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Страница 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Страница 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...