4-1
Section
Controller
55
Use the following procedure to prepare and connect the communications con-
nectors.
1, 2, 3...
1. Attach crimp terminals to the stripped ends of the communications wires.
Check the alignment of the connector and insert the wires into the correct
holes in the connector.
•
Recommended Cable: MVVS 4CX0.5Sq
Use two of the cable’s wires as the RS-485 interface lines and the other
two wires as the SYNC lines. Connect the shield wire to the ground termi-
nal. See Wiring SYNC Signals on page 48 for details.
•
Recommended Terminals: Nihon Weidmuller H-sleeve Series
Crimp terminal
Wire
Insert the wire into the pin terminal and crimp it. Nihon Weidmuller sells the
PZ-series Crimping Tool for crimping these terminals.
2. Tighten the connector’s set screws to secure each of the wires in the con-
nector. A regular screwdriver that tapers at the end may not fit into the screw
hole, so use a screwdriver with a tip and shaft that are the same width. Tight-
en the screws to a proper torque (about 0.5 N
@
m).
Precision flat-blade
screwdriver that does
not taper at the tip.
OMRON sells the following
screwdriver that is ideal for
this application.
Side
Face
0.6 mm
3.5 mm
Preparing and Installing