6-6
Section
Functions
107
6-6-4 Address Setting
Set the start address and end address to determine the area where data is to be
read, written, or tests conducted.
In the following example, the start address is set to 5Ah and the end address is
set to 6Fh.
The start address and end address are
selected with the Left and Right Keys.
By pressing the ADRS Key, the
Programming Console is ready to accept
address input. The 0 through 9 and the A
through F Keys are available.
Be sure to set the end address to the same
or a larger value than the value of the start
address, otherwise an address error will
result when communications start. An
address error will also occur if an address
exceeding F0h is set.
In the following example, the start address is set to 5Ah and the end address is
set to 6Fh.
The start address and end address are selected
with the Left and Right Keys.
By pressing the ADRS Key, the Programming
Console is ready to accept address input. The 0
through 9 and the A through F Keys are
available.
Be sure to set the end address to the same or a
larger value than the value of the start address,
otherwise an address error will result when
communications start. An address error will also
occur if an address exceeding F0h is set.
Note
1. Be sure to set the end address to the same value or larger value than that of
the start address.
2. Make sure that the specified data is within the memory capacity of the ID
Tag.
Read Data
Write Data