7-4
Section
Maintenance and Inspection
121
7-3-2 Error Lists
The details of the following errors are recorded in the Controller. The error codes
and error messages can be read through the Programming Console.
Communications Error between Controller and Host
Response
code
Name
Likely cause
10
Parity error
•
There is a mistake in the settings for communications between the host and
11
Framing error
Controller (baud rate or communications format).
•
12
Overrun error
•
There is a problem with the RS-232C or RS-485 wiring. (Check termination
and ambient noise.)
13
BCC error
•
There is a problem with the BCC calculation method.
•
There is a problem with the RS-232C or RS-485 wiring. (Check termination
and ambient noise.)
14
Format error
•
The command frame was incorrect.
(Illegal character, incorrect location of STX/ETX, etc.)
18
Frame length error
(Illegal character, incorrect location of STX/ETX, etc.)
•
The command could not be sent. (The conditions required for execution of the
command were not met.)
Communications Error between Controller and ID Tag
Response
code
Name
Meaning
70
Communications error
•
The distance between the Antenna and ID Tag is incorrect or the ID Tag’s
speed is incorrect.
•
The FG or power supply wiring is incorrect (ambient noise).
•
There is too much noise around the Antenna. (Ground or shield the noisy de-
vice or change the Antenna location.)
71
Verification error
The ID Tag has reached its life expectancy (100,000 write operations).
72
No Tag error
The distance between the Antenna and ID Tag is incorrect.
7A
Address error
•
The command’s address and number of bytes settings are incorrect.
•
The specified address range exceeds the memory area of the ID Tag.
7B
Not write area error
The distance between the Antenna and ID Tag was incorrect when the write
command was executed.
7C
No Antenna connected
error
No Antenna is connected or the Antenna is connected incorrectly.
7D
Protection error
•
An attempt was made to write to a write-protected page.
•
The command’s address and number of bytes settings are incorrect.
7E
ID system error 1
•
The environmental conditions are not within the Tag’s specifications. (ID Tag
7F
ID system error 2
damaged.)
•
The ID Tag being used does not support the operation.
7-4
Maintenance and Inspection
The V700 Series must be inspected on a daily or regular basis so that the func-
tions of the V700 Series can be used in good condition.
The V700 Series consists of semiconductors that last almost indefinitely. The
following malfunctions may, however, result due to the operating environment
and conditions.
1, 2, 3...
1. Element deterioration due to overvoltage or overcurrent.
2. Element deterioration due to continuous stress caused by high ambient
temperature.
3. Connector contact faults or insulation deterioration due to humidity and
dust.
4. Connector contact faults or element corrosion due to corrosive gas.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]