Summary of axis types and control modes
The following table lists the axis types and their recommended
modes for speed control, position control and torque control.
/i
ATYPE SERVO Mode
Comment
40
0
Position
(MECHATROLINK-II)
The position loop is closed in the Servo Driver. No new
motion command is allowed.
40
1
Position
(MECHATROLINK-II)
Recommended mode for position control with MECHA-
TROLINK-II axes.
41
0
Speed
(MECHATROLINK-II)
Recommended mode for speed control with MECHA-
TROLINK-II axes. Set the speed with
S_REF
.
41
1
Position
(MECHATROLINK-II)
The position loop is closed in Trajexia. This gives lower
performance than closing the position loop in the Servo
Driver.
42
0
Torque
(MECHATROLINK-II)
Recommended mode for torque control with MECHA-
TROLINK-II axes. Set the torque with
T_REF
.
42
1
Postion via torque
(MECHATROLINK-II)
The position loop is closed in Trajexia. The output of
the position loop is sent as the torque reference to the
Servo Driver.
44, 46,
47, 48
0
Speed
(Flexible Axis)
Recommended mode for speed control with Flexible
Axis.
44, 46,
47, 48
1
Position
(Flexible Axis)
The position loop is closed in Trajexia. Recommended
mode for position control with Flexible Axis.
I51E-EN-03.book Seite 47 Donnerstag, 28. Juni 2007 1:05 13