Hardware reference
HARDWARE REFERENCE MANUAL
113
Revi
si
on 3.0
fig. 60
I/O Cable:
The following table shows the standard I/O cable models. The
standard cable is used for both IO2310 and IO2330 modules.
/i
Station number and dipswitch settings
fig. 61
Station Number switch sets the station number of the module in the
MECHATROLINK-II system. The range is 0 to F.
Use a unique station number for each unit if two or more units are
connected.
fig. 62
Dipswitch settings:
The dipswitch sets the communication parameters.
/i
The data in the parentheses indicate the MECHATROLINK-II
addresses.
Name
Model
Length (m)
I/O Cable
JEPMC-W5410-05
0.5
JEPMC-W5410-10
1
JEPMC-W5410-30
3
4
3
2
1
7
6
5
8
B
A
9
C
F
E
D
0
ON
OFF
1
2
3
_
Display
(Switch No.)
Name
Status
Function
-
Reserved by system
-
Be sure to turn it
off
3
MECHATROLINK-II upper-
place address setting
on
7xh
off
6xh
2
I/O byte setting
on
32-byte mode
1
Baud rate setting
on
10 Mbps