Hardware reference
HARDWARE REFERENCE MANUAL
54
Revi
si
on 3.0
3.2
All units
3.2.1
System installation
fig. 3
A Trajexia system consists of these units:
•
A Power Supply Unit.
•
A TJ1-MC__ (Motion Controller Unit). This can be one of these:
-
TJ1-MC16. It supports 16 real or virtual axes, and 16 axes
in total.
-
TJ1-MC04. It supports 5 real and up to 16 virtual axes, 16
axes in total.
•
Up to 7 expansion units.
•
A TJ1-TER (Terminator Unit).
The expansion units (unit numbers 0-6) can be arranged in any
order. The TJ1-MC__ autodetects all units.
A Trajexia system with a TJ1-MC16 can include:
•
0 to 4 TJ1-ML__ units (MECHATROLINK-II Master Unit).
•
0 to 7 TJ1-FL02 units.
•
0 or 1 TJ1-PRT (PROFIBUS-DP Slave Unit) or TJ1-DRT units
(DeviceNet Slave Unit)
1
.
A Trajexia system with a TJ1-MC04 can include:
•
0 to 4 TJ1-ML__ units.
•
0 to 3 TJ1-FL02 units.
•
0 or 1 TJ1-PRT or TJ1-DRT units
•
-1
Unit number:
0
1
2
3
4
5
6
1. Trajexia does not support both a TJ1-PRT and a TJ1-DRT unit in
the same system.
I51E-EN-03.book Seite 54 Donnerstag, 28. Juni 2007 1:05 13