MECHATROLINK connectors (CN1A & CN1B)
fig. 38
Connect to the MECHATROLINK-II network as in the figure using a
suitable MECHATROLINK-II cable. Both connectors are parallelled
so you can connect both cables to both connectors. Connect a
MECHATROLINK-II terminator resistor in one of the connectors if
the Servo Driver is the last device in the network.
CN4 Full-closed encoder connector
CN4 is for connecting a full-closed encoder, that is, the position is
controlled based in one external encoder, and the speed and
torque loop based in the motor encoder. This is used when you
install the motor in machines where you have to measure directly
on the load because either:
•
There is slip or backlash in the mechanical transmission.
•
The precision required is very high.
The supported encoder is line driver and the pinout is shown in the
figure.
The table shows the CN4 connector terminal layout and connector
specifications.
I51E-EN-03.book Seite 88 Donnerstag, 28. Juni 2007 1:05 13