Precautions for Correct Use
To import a CJ-series Unit configuration, you need to set this as follows.
• Set slot numbers so that they do not conflict in the Expansion Rack configuration.
• Set slot numbers so that they are sequential numbers that start from 0.
• Set slot numbers so that they are not more than the maximum unit number of the CPU Rack
for NJ-series CPU Units.
3-3-5
Device Variables
Set the component data for models that support the connector function for device variables as follows.
PLC Connection Points
Set the target I/O ports as follows.
ID
Property name
Setting value
20402
Symbolic address
Device variable name
20011
Function text
Device variable comment
Precautions for Correct Use
• To enter a device variable comment, you need to set the device variable name.
• Set device variable names so that they do not conflict in the controller configuration. Device
variables with conflicting variable names will not be imported.
• When
ID: 20438 Deactivated I/O connection point
is selected, device variables will not be im-
ported to the Sysmac Studio even if their device variable names and device variable com-
ments are entered.
3-3-6
Power Supply Units
PLC Box
Leave all the setting values of the PLC box blank.
ID
Property name
Setting value
20161
Configuration project
Blank
20408
Station ID
Blank
20427
Rack ID
Blank
20410
PLC card is placed on rack ID
Blank
20411
Position (slot / module)
Blank
20253 1
CPU: Name [1]
Blank
3 Setting EPLAN Electric P8
3-14
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)